2-35
PC210/240-ENG
11.14 FUSE
NOTICE
Before replacing a fuse, be sure to turn off the starting switch.
The fuses protect the electrical equipment and wiring from burning
out.
If the fuse becomes corroded, or white powder can be seen, or the
fuse is loose in the fuse holder, replace the fuse. Replace a fuse with
another of the same capacity.
Fuse capacity and name of circuit
No Fuse capacity Name of circuit
y
10A
Governor/Pump controller
x
10 A
Solenoid valves
c
20 A
Air Conditioner (motor)
v
20 A
Right head lamp, Work lamps
(Boom LH & RH), Engine room lamp,
Heated seat.
b
20 A
Cigarette lighter, Heater,Window
washer, Left knob button
n
10 A
Horn
m
15 A
Wiper controller
h
20 A
Cab mounted work lamps (x3), Beacon
j
20 A
Lower wiper, Refuelling pump
j
10 A
Key switch signal
k
15 A
Work lamps
(Left hand deck, counterweight)
l
10 A
Spare
m
10 A
Alarm buzzer, Monitor
n
20 A
Battery relay, Ribbon heater, Start signal
o
10 A
Cab lamp, Radio
p
10A
Spare fuse
q
10A
Spare fuse
r
15A
Spare fuse
s
20A
Spare fuse
11. EXPLANATION OF COMPONENTS
Содержание PC210
Страница 2: ......
Страница 44: ...1 32 PC210 240 ENG MEMO ...
Страница 45: ...2 1 PC210 240 ENG OPERATION ...
Страница 146: ...2 102 PC210 240 ENG ...
Страница 147: ...3 1 PC210 240 ENG MAINTENANCE ...
Страница 167: ...3 21 PC210 240 ENG 22 PERIODIC REPLACEMENT OF SAFETY CRITICAL PARTS m n ...
Страница 220: ...3 74 PC210 240 ENG ...
Страница 221: ...4 1 PC210 240 ENG SPECIFICATIONS ...
Страница 226: ...4 6 PC210 240 ENG 25 SPECIFICATIONS PC240NLC 6K The values given are the values for PC240NLC 6K ...
Страница 231: ...4 11 PC210 240 ENG 25 SPECIFICATIONS ...
Страница 232: ...4 12 PC210 240 ENG ...
Страница 233: ...5 1 PC210 240 ENG OPTIONS ATTACHMENTS ...
Страница 266: ...5 34 PC210 240 ENG 5 32 ...