3-31
PC210/240-ENG
10. When the water is completely clean, stop the engine, close drain
valve
b
, wrap the drain plug with seal tape, then close drain plug
c
.
11. Install the undercover.
12. Add cooling water until it overflows from the water filler.
13. To remove the air in the cooling water, run for five minutes at low
idling, then for another five minutes at high idling. When doing this,
leave radiator cap
a
off.
14. After draining off the cooling water of reserve tank
d
, clean the in-
side of the reserve tank and refill the water between FULL and LOW
level.
15. Stop the engine, wait for about three minutes, add cooling water, up
to near the radiator water filler port, then tighten cap
a
.
d
24. SERVICE PROCEDURE
Содержание PC210
Страница 2: ......
Страница 44: ...1 32 PC210 240 ENG MEMO ...
Страница 45: ...2 1 PC210 240 ENG OPERATION ...
Страница 146: ...2 102 PC210 240 ENG ...
Страница 147: ...3 1 PC210 240 ENG MAINTENANCE ...
Страница 167: ...3 21 PC210 240 ENG 22 PERIODIC REPLACEMENT OF SAFETY CRITICAL PARTS m n ...
Страница 220: ...3 74 PC210 240 ENG ...
Страница 221: ...4 1 PC210 240 ENG SPECIFICATIONS ...
Страница 226: ...4 6 PC210 240 ENG 25 SPECIFICATIONS PC240NLC 6K The values given are the values for PC240NLC 6K ...
Страница 231: ...4 11 PC210 240 ENG 25 SPECIFICATIONS ...
Страница 232: ...4 12 PC210 240 ENG ...
Страница 233: ...5 1 PC210 240 ENG OPTIONS ATTACHMENTS ...
Страница 266: ...5 34 PC210 240 ENG 5 32 ...