3-51
PC210/240-ENG
WARNING
24.5 EVERY 250 HOURS SERVICE
24.5.1 CHECK OIL LEVEL IN FINAL DRIVE CASE, ADD
OIL
• The oil is at high temperature immediately after the machine
has been operated. Wait for the oil to cool down before start-
ing the operation.
• If there is still pressure remaining inside the case, the oil or
plug may fly out;
Loosen the plug slowly to release the pressure.
•
Prepare a handle.
1.
Set the TOP mark at the top, with the TOP mark and plug
P
perpen-
dicular to the ground surface.
2.
Remove plug
F
using the handle. When the oil level reaches a point
10 mm below the bottom of the plug hole, the correct amount of oil
has been added.
3.
If the oil level is to low, install plug
F
, operate the travel levers, and
drive forward or in reverse to rotate the sprocket one turn.
Then repeat Step 2 to check again.
4.
If the oil; is still low, add engine oil through the hole in plug
F
until the
oil overflows.
For details of the oils to use, see 20. “USE OF FUEL, COOLANT AND
LUBRICANTS ACCORDING TO AMBIENT TEMPERATURE.”
5.
After checking, install plug
F
.
24. SERVICE PROCEDURE
Содержание PC210
Страница 2: ......
Страница 44: ...1 32 PC210 240 ENG MEMO ...
Страница 45: ...2 1 PC210 240 ENG OPERATION ...
Страница 146: ...2 102 PC210 240 ENG ...
Страница 147: ...3 1 PC210 240 ENG MAINTENANCE ...
Страница 167: ...3 21 PC210 240 ENG 22 PERIODIC REPLACEMENT OF SAFETY CRITICAL PARTS m n ...
Страница 220: ...3 74 PC210 240 ENG ...
Страница 221: ...4 1 PC210 240 ENG SPECIFICATIONS ...
Страница 226: ...4 6 PC210 240 ENG 25 SPECIFICATIONS PC240NLC 6K The values given are the values for PC240NLC 6K ...
Страница 231: ...4 11 PC210 240 ENG 25 SPECIFICATIONS ...
Страница 232: ...4 12 PC210 240 ENG ...
Страница 233: ...5 1 PC210 240 ENG OPTIONS ATTACHMENTS ...
Страница 266: ...5 34 PC210 240 ENG 5 32 ...