Vers. 100822 Page 9
25) Torq min
– Minimum torque:
The minimum torque and maximum torque options allow the user to
set the acceptable torque range for each single application. When the reached torque is within this range,
“Screw OK” will be displayed on the status bar and the green led will light up. If the reached torque is outside
this range, “error minimum torque” or “error maximum torque” will be displayed and the red led will light
up. You can set the torque range from 0 to ‘Torq Max-0.01 Nm’ in steps of 0.01 Nm.
The minimum torque option allows to set the lowest value of the torque range. When Calibration is OFF, the
minimum torque value automatically sets on 0 Nm.
The selection of the torque value is carried out by entering the digit cell by cell.
26) Torq max – Maximum Torque:
The minimum torque and maximum torque options allow the user to
set the acceptable torque range for the single application. When the reached torque is within this range, “Screw
OK” will be displayed on the status bar and the green led will light up. If the reached torque is outside this
range, “error minimum torque” or “error maximum torque” will be displayed. You can set the torque range
from ‘Torq Min+0.01 Nm’ to 55 Nm at intervals of 0.01 Nm.
The maximum torque option allows to set the highest value of the torque range. When Calibration is OFF the
maximum torque value automatically sets on 55 Nm.
The selection of the torque value is carried out by entering the digit cell by cell.
- - - - - M E N U - - P R : 1 - - - - -
2 7 ) I n s . b a r c o d e
2 8 ) S e r i a l P R T : o f f
2 9 ) F u n c T & A : o f f
27) Ins. barcode:
to scan a barcode and recall the desired program. To be used in combination with option
4. of the Sequence Menu.
IMPORTANT: Barcode can be ONLY numeric.
28) Serial PRT:
Serial print: from OFF to 5.
When OFF, no print.
If it is set up to 5,
this value identifies the number of line feeds between a string and another.
- - - - - M E N U - - P R : 1 - - - - -
2 9 ) F u n c T & A : o f f
3 0 ) S t a r t i n g T o r : - - -
3 1 ) A n g . m i n : - - - -
29) Func T&A–T&A function mode:
You can activate the Torque & Angle function. Set OFF when you
don’t need this function. When you set ON you can choose among six working conditions (see T&A specific
instructions).
30) Starting Tor – Starting torque:
If T&A option is set on Tor mode (See T&A paragraph), you can set
the torque threshold the angle starts to be read from. When T&A is set on angle mode (see T&A paragraph),
you can set the torque threshold the angle starts to be carried out from.
In # mode, the torque threshold must be included in the range of values relating to the pre-set speed and model.
31) Ang. min – Minimum angle:
Minimum angle threshold. You can set it when T&A is set on Tor, T/in
or T/lv (see T&A specific instructions). The minimum angle the operator can set is 5°.