Vers. 100822 Page 3
K o l v e r S . r . l .
E D U 2 A E / T O P / T A
V e r s i o n 6 . 0 0
l o a d i n g . . .
When turned on and the screwdriver is connected, the unit is set to % mode and the display will contain the
following information:
P L U T O 1 0 T % : 1 0 %
P R : 1 S : 0 / 0 1
T : A :
r e a d y
1-
Reached torque level in Nm, lbf.in or kgf.cm (in % mode, only if
Show Torque
function is active)
2-
Program number or sequence
3-
Screwdriver model
4-
Torque level in percentage
5-
Screw count: done screws/total screws
6-
Angle value in degrees
7-
Status bar (ready, errors, etc…)
FRONT PANEL KEYBOARD
To enter the menu press the
ESC
key for 2 seconds.
Select the line by pressing
or
then press
OK
(the symbol
will turn into ). Press the or
to select the required value
and then confirm through
OK
(or
ESC
if you don’t want to save
the value).
The selected values will be immediately operational, even if you
are still in the menu screen.
Repeat the sequence for all the
parameters you wish to change and then push
ESC
to return to
the main screen.
Press
RESET
for 3 sec should you need to reset the screw, the
program or the sequence. If you want to see all the set parameters
press
for 2 seconds, however you cannot modify the displayed
parameters on this screen.
LEDS ON FRON PANEL
GREEN LED VERDE: indication of
Screw OK
.
YELLOW LED: indication of
Programm End
or
Sequence End
.
RED LED: any indication of error.
2