background image

 

Vers. 100822                                                                                                                                            Page 15

 

 

 
 
In case of error, you will see: 

 

-  -  -  -  -  -  -  - S T E P -  -  1  -  -  -  -  - 

                                       
         

S  t  a  r  t    t  e s  t           

E r  r  . R e p e  a  t    S c  r  e w  i  n g   

 
Just repeat the test. 

 

6. Press ESC to abort the calibration process. 
Press OK, then the display will show: 

 

-  -  -  -  -  -  -  - S T E P -  -  1  -  -  -  -  - 

E n  t  e  r    t  o  r  q u e     v a  l  u e  :   

           

0 0  .  0 1 N m               

 

                                     

 

Set the torque value by selecting each digit individually pressing  and   and press OK to confirm it, then 
press OK again to save. You will see: 
 
 

 

-  -  -  -  -  -  -  - S T E P -  -  2  -  -  -  -  - 

       

E n  t  e  r    t  h e               

 

p e  r  c e n  t  a g e  :            2 5 % 

                                       

 

7. Set the percentage of the second torque to 25% by pressing   and press OK. 
(25% is just an example). 
 
8. Repeat the procedures described on points 4 and 5. 
9. When calibration ends, “Setting end” will be displayed. You will hear two beep sounds, too. 
Now you are ready to work and see the correct torque on the display. 
 
WARNING: 

-

 

Calibration  values  will  be  referred  to  the  parameters  of  the  control  unit  which  are  set  during 
calibration, i.e. if you modify speed or torque, the unit will need to be recalibrated. During calibration 
when a screwing is not carried out correctly or if for any reasons you’re not sure of the torque value 
it is possible to repeat it. A wrong screwing can affect the precision of the calibration.  

-

 

Calibration is carried out for two torque levels optionally chosen. The minimum calibration interval 
is 5% (example: if I have to work at 50%, I can calibrate at 45% and 55%). In this case, if for any 
reasons I need to work at torque percentages which are lower or higher than the min-max ones set 
during the calibration, they will be analyzed and displayed anyway but since they won’t be based on 
effective data  the torque value displayed may be not accurate.  

-

 

During calibration it is not possible to go back to the previous screen. Press ESC to stop calibration 
and then repeat the screwing cycles.  

 

Содержание 034000/TOP/TA

Страница 1: ...ONFORMITY KOLVER S r l declares that the new tool here described control unit model EDU2AE TOP TA is in conformity with the following standards and other normative documents 2006 42 CE LVD 2014 35 UE...

Страница 2: ...through a percentage the tightening and unscrewing torque values are set directly as the desired value and in the selected unit of measurement Torque setting Model Torque Nm Speed rpm Unit Min Max MI...

Страница 3: ...ESC key for 2 seconds Select the line by pressing or then press OK the symbol will turn into Press the or to select the required value and then confirm through OK or ESC if you don t want to save the...

Страница 4: ...it the buttons the unit mode date and time the firmware version the serial number and the cycles done USB Options It indicates the menu section where you can view upload and create programs setting of...

Страница 5: ...ired torque as a percentage of the torque range of the selected screwdriver For example for a Pluto10 a 50 setting will result in a torque in the area of 4 5 Nm The torque range is always referred to...

Страница 6: ...ed Time is ON 9 Final Spd Final Speed You can select any speed value of the screwdriver between nominal maximum speed given in the catalogue and the minimum speed of every single screwdriver see table...

Страница 7: ...crewdriver between the maximum and the minimum specific speed of every single screwdriver see table with technical data In Unit mode even the reverse speed is linked to the relative table of the screw...

Страница 8: ...K when ON press OK at the end of each program When OFF the control unit resets automatically at the end of each program 20 Press ESC when ON press ESC to reset the control unit When OFF the control un...

Страница 9: ...set the highest value of the torque range When Calibration is OFF the maximum torque value automatically sets on 55 Nm The selection of the torque value is carried out by entering the digit cell by ce...

Страница 10: ...ed S E QU E NC E ME N U 3 E x t b o x o f f 4 M o d b a r c o f f 5 I n s b a r c o d e S e q 3 Ext box It allows to enable or disable the external control IMPORTANT It is mandatory to select ON to wo...

Страница 11: ...t Options OP T I O N S ME N U OK c h a n g e E S C q u i t 1 L a n g u a g e E N 2 C h a n g e p a s s w o r d 1 Language This option allows to choose among the languages available English French Germ...

Страница 12: ...nected screwdriver will be set and the relative default values for torque and speed will be loaded If the user selects No and leaves the screwdriver connected the warning Connect right model which is...

Страница 13: ...e USB drive and select the file SETxx KOL you desire The EDU control unit recognizes only files as SETxx KOL see EDU EXPAND part S e l e c t P r o g r a m S E T 0 0 KOL OK c o n f i r m E S C q u i t...

Страница 14: ...wing screen will appear on the display ME N U 2 3 C a l i b r a t i o n o n 3 Press OK to confirm If you choose OFF calibration will be interrupted and no torque value will be displayed You choose ON...

Страница 15: ...bration values will be referred to the parameters of the control unit which are set during calibration i e if you modify speed or torque the unit will need to be recalibrated During calibration when a...

Страница 16: ...w is correctly tightened If the torque and or angle are outside the preset values the screw will be considered as incorrectly tightened In this case the red led will light up and the message Error Max...

Страница 17: ...n led will light up and the message tightening OK will be displayed on the status bar If the screwdriver stops before reaching the preset angle the tightening will be considered not ok the red led wil...

Страница 18: ...0 5 1 9 2 500 0 5 1 0 4 5 8 9 5 1 10 2 550 0 6 1 1 5 4 9 7 6 2 11 2 600 0 7 1 2 6 2 10 6 7 2 12 2 650 0 7 1 3 6 2 11 5 7 2 13 3 700 0 8 1 4 7 1 12 4 8 2 14 3 800 0 9 1 5 8 0 13 3 9 2 15 3 850 PLUTO 3...

Страница 19: ...2 5 11 6 22 1 13 3 25 5 60 1 5 4 5 13 3 39 8 15 3 45 9 80 2 0 6 1 17 8 54 0 20 4 62 2 100 2 1 7 7 18 6 68 2 21 5 78 5 130 2 2 9 8 19 5 86 7 22 5 99 9 170 2 3 11 4 20 4 100 9 23 5 116 2 210 2 4 12 7 2...

Страница 20: ...X min MAX rpm 4 2 14 0 37 2 123 9 42 9 142 8 20 7 4 25 1 65 5 222 2 75 5 255 9 30 8 4 33 6 74 4 297 4 85 7 342 6 40 8 9 39 3 78 8 347 8 90 8 400 7 50 9 4 43 2 83 2 382 4 95 9 440 5 60 9 5 45 6 84 1 40...

Страница 21: ...3 3 52 0 600 1 4 5 5 12 4 48 7 14 3 56 1 700 1 5 5 9 13 3 52 2 15 3 60 2 800 1 7 6 1 15 1 54 0 17 4 62 2 850 PLUTO 8 ANG Nm Lbf in Kgf cm min MAX min MAX min MAX rpm 1 0 1 7 8 9 15 0 10 2 17 3 110 1 2...

Страница 22: ...connectors allow to enable functions through inputs and to take signals through outputs The inputs are activated by connecting them to ground A positive voltage must NEVER be brought to these inputs B...

Страница 23: ...Vers 100822 Page 23 to protection displaying the message output disable To restore the outputs after a protection turn off and turn on the unit again...

Страница 24: ...ing screwing Signal is 24V 5 SCREW OK Correct screw signal The green led on the front panel will switch on Signal is 24V INPUT 6 T A INPUT External input for making the control unit start to count the...

Страница 25: ...nu remote OK key function 4 ESC EXT If enabled see point 4 OK ESC in the option menu ESC key function to reset remote errors 5 RESET EXT If enabled see point 4 OK ESC commands in the option menu it re...

Страница 26: ...nal works in parallel with the yellow led on the front panel 4 SEQUENCE END It indicates the end of a sequence if enabled 5 NOK T A It activates if any angle error occurs 6 PR OK It activates at the e...

Страница 27: ...UTPUT 3 It indicates you re using program 3 4 OUTPUT 4 It indicates you re using program 4 5 OUTPUT 5 It indicates you re using program 5 6 OUTPUT 6 It indicates you re using program 6 7 OUTPUT 7 It i...

Страница 28: ...point 4 OK ESC in the option menu ESC key function to reset remote errors 16 RESET EXT If enabled see point 4 OK ESC in the option menu it resets program or sequence according to the preset function...

Страница 29: ...rcuit will result in the stop of the unit To re activate signals it is necessary to switch off the unit for 5 6 seconds check connections and output loads then switch the unit on CORRECT SCREWS MESSAG...

Страница 30: ...yed on the status bar the lever has been released before the runtime has been achieved 5 Under min time is displayed on the status bar the torque signal is displayed below the pre set minimum time 6 O...

Страница 31: ...led or disabled through PROGRAM MENU see point 18 on the program menu 18 Reverse torque error is displayed on the status bar The torque signal is displayed while loosening but only if it s set on max...

Страница 32: ...t or incorrect OK the torque has been correctly reached all the selected parameters are satisfied and the control unit will give out a beep sound of 0 5 sec NOK the torque has been reached during ramp...

Страница 33: ...e to use EDU EXPAND Double click the icon program and this is the main view New program to load a new program Load from file it loads all programs sequences and option settings from a previously saved...

Страница 34: ...rive and upload to the unit or recall with EDU EXPAND Upload to unit it uploads all the setting to the EDU control unit Connect the unit to your computer through miniUSB or RS232 Switch the unit on Cl...

Страница 35: ...connect the USB drive to the control unit the unit creates a folder where the report of the screwing done will be saved The folder is named as the serial number of the unit The text file which contai...

Страница 36: ...Vers 100822 Page 36 EXPLODED VIEW EDU2AE TOP TA 6 00...

Страница 37: ...TA 1 819006 14 USB Flat cable 1 872474 15 USB Device 1 852424 16 USB Pen drive 1 872475 17 M12 8pin nut ferrite connector 1 201766 LTA 18 M3 Washer h0 5 mm 4 800042 19 Spacer 15mm dest 4 8 mm 4 890004...

Страница 38: ...e free of charge such items 3 This guarantee does not cover repair or replacement required as a consequence of products which have been abused misused or modified or which have been repaired using not...

Отзывы: