2
Technical description
2.1
Safety Instructions
l
Only properly qualified personnel are permitted to carry out activities
such
as
transport,
installation,
commissioning
and
maintenance.
Properly qualified persons are those who are familiar with the transport,
assembly, installation, commissioning and operation of the product, and
who have the appropriate qualifications for their job. The qualified
personnel
must
know
and
observe
the
following
standards
and
regulations:
IEC 364 and CENELEC HD 384 or DIN VDE 0100
IEC Report 664 or DIN VDE 0110
national accident prevention regulations or BGV A2
l
The manufacturer of the machine must produce a hazard analysis for the
machine and take appropriate measures to ensure that unforeseen
movements do not result in personal injury or material damage.
l
Read this documentation before carrying out the installation and
commissioning. Incorrect handling of the servo amplifier can lead to
personal injury or material damage. It is vital that you keep to the
technical data and information on connection requirements (nameplate
and documentation).
l
Do not open or touch the equipmen during operationt. Keep all covers
and cabinet doors closed during operation. Touching the equipment is
allowed during installation and commissioning for properly qualified
persons only. Otherwise, there are deadly hazards, with the possibility
of death, severe injury or material damage.
—
During operation, servo amplifiers may have uncovered live
components, depending on their level of enclosure protection.
—
Control and power connections may be live, even though the
motor is not rotating.
—
Servo amplifiers may have hot surfaces during operation.
Surface can reach temperatures above 80°C.
l
Discharge your body before touching the servo amplifier. The servo
amplifiers contain electrostatically sensitive components which may be
damaged by incorrect handling. Avoid contact with highly insulating
materials (artificial fabrics, plastic film etc.). Place the servo amplifier on
a conductive surface.
l
Never undo any electrical connections to the servo amplifier while it is
live. There is a danger of electrical arcing with damage to contacts and
personal injury.
Wait at least five minutes after disconnecting the servo amplifier from
the main supply power before touching potentially live sections of the
equipment (e.g. contacts) or undoing any connections. Capacitors can
still have dangerous voltages present up to five minutes after switching
off the supply power. To be sure, measure the voltage in the DC Bus link
and wait until it has fallen below 40V.
SERVO
STAR
®
400 Installation Manual
7
Kollmorgen
07/05
Technical description
Содержание SERVOSTAR 400
Страница 31: ...3 4 4 Connector assignments SERVOSTAR 400 Installation Manual 31 Kollmorgen 07 05 Installation...
Страница 59: ...5 3 2 3 Status display on the master SERVOSTAR 400 Installation Manual 59 Kollmorgen 07 05 Setup...
Страница 62: ...This page has been deliberately left blank 62 SERVOSTAR 400 Installation Manual Setup 07 05 Kollmorgen...
Страница 73: ...This page has been deliberately left blank SERVOSTAR 400 Installation Manual 73 Kollmorgen 07 05 Appendix...