3.4.5.2
Requirements to cables
Further information on the chemical, mechanical and electrical characteristics of the
cables can be obtained from our customer support.
Insulation material
Sheathing
PUR (polyurethane, code 11Y)
Core insulation
PETP (polyesteraphthalate, code 12Y)
Capacitance
Motor cable
less than 150 pF/m
RES/encoder cable
less than 120 pF/m
Technical data
—
The brackets in the cable designation indicate the shielding.
—
All cables are suitable for use as trailing cables.
—
The technical data refer to the use as moveable cables.
operating life : 1 million bending cycles
—
The permissible operating temperature range is from -30°C to +80°C.
—
All cables are colour-coded according to IEC 757.
Cores
[mm²]
External diameter
[mm]
Bending radius
[mm]
Remarks
(4x1.0)
10
100
Motor cable, 25m max.
(4x1.0+(2x0.75))
10.5
100
Motor cable with extra cores
for controls, 25m max.
(4x2x0.25)
6.9
60
twisted pairs
(7x2x0.25)
9.9
80
(10x2x0.14)
8.8
80