AKD PROFINET | 4 Installation and Setup
4.4.1 Dependency Service channel (WorkBench) and PROFINET
WorkBench and PROFINET use the same IP communication channel to communicate with
the drive so changing the IP address has implications for both interfaces.
There are several options for assigning the IP address for WorkBench and PROFINET as
described in the AKD User Guide:
l
DHCP, AutoIP
l
Static IP addressing
o
Via rotary switches (Address area 192.168.0.xx)
o
Via ASCII commands IP.ADDRESS, IP.SUBNET. IP.GATEWAY
l
PROFINET Devices (only): DCP
Once you have changed the IP address via DCP (e.g. through the steps above), the IP.* para-
meters stored in the drive are overwritten. Should you need to use DHCP or static IP address-
ing later, you must use WorkBench to set, the IP.MODE to something other than 1. See AKD
User Guide for details on the mode you would like to use.
4.4.2 Reset of IP Address parameters
If the AKD can not be found in the network, as a last resort, reset all IP address parameters
to their default values.
This is done by setting the rotary switches to 0 and holding the B1 button longer than 5
seconds. After this, the current IP address setting will be lost and the IP address is restored
to default settings (after power cycle):
If rotary switches are zero, the DHCP and AutoIP is enabled.
If rotary switches are not zero, the static IP address is 192.168.0.xx (xx rotary switches) and
subnet mask 255.255.255.0.
18
Kollmorgen | December 2014
Содержание AKD PROFINET RT Communication
Страница 8: ...AKD PROFINET 2 General 8 Kollmorgen December 2014...
Страница 30: ...AKD PROFINET 6 PROFIDRIVE over PROFINET IO 6 3 General State Machine 30 Kollmorgen December 2014...
Страница 46: ...AKD PROFINET 7 Sample Projects 7 Sample Projects 7 1 Sample S7 Project 47 46 Kollmorgen December 2014...
Страница 52: ...This page intentionally left blank AKD PROFINET 9 Index 52 Kollmorgen December 2014...