Select the radio button
Use IP parameters
: then enter a new IP address and subnet mask to
AKD. Click the
Assign IP Configuration
button for the change to take effect
Use the same popup to change the device name at this time by entering a name in the
Device Name
fields and clicking on the
Assign Name
button. Each device connected to the
same IO connection must have a unique name. The PROFINET device name for AKD is
derived from the AKD DRV.NAME parameter. The PLC, which acts as PROFINET IO-Con-
troller. will use the
Device Name
as address and can change the IP address for each
Device
Name
.
You will usually see a status message that indicates that the change was successful and the
AKD display will show the new address. If you receive a failure message, make sure that no
IO connection is currently running, then retry the address or name change.
A current connection of WorkBench to AKD will be disconnected when the IP address is
changed. When this happens, reconnect to the new IP address.
AKD PROFINET | 4 Installation and Setup
Kollmorgen | December 2014
17