background image

 如何安装交流电源盒

(若用户另购

交流电源盒

,

具体安装详见其说明书

)

HOW TO INSTALL THE AC/DC 
TRANSFORMER (ONLY USED 
WITH TOUCHLESS FAUCET, AC)

AC/DC transformer

交流电源盒

一个交流电源盒供一个感应龙头

220V

交流电

Connect AC 220V

Switch

开关

Wire Tube

穿线管

Wire connection pattern for one to one

Faucet

感应龙头

Wire connection pattern for one to two

一个交流电源盒供两个感应龙头

Connect to 
electrical Source

接交流电源

注意:禁止将交流

AC220V

接入直流

DC

接线端。

Connect to 
Faucet

接感应龙头

Connect to 
electrical Source

接交流电源

Connect to 
Faucet

接感应龙头

Note: Not allowed connect AC 220V electrical source to DC wire connector of AC/DC transformer

Faucet

感应龙头

Wire Tube

穿线管

Switch

开关

Wire

连接线

Wire Tube

穿线管

AC/DC 
transformer

交流电源盒

Faucet

感应龙头

220V

交流电

Connect AC 220V

外螺纹

8

1205259-2-A

用户自备角阀

G1/2

外螺纹

Please user prepare 
external thread check 
valve G1/2

用户自备角阀

G1/2

Please user prepare 
external thread check 
valve G1/2

Содержание LOURE 98452T-CP

Страница 1: ...When installing DC type faucets pay special attention to the directions of battery electrodes Tighten the battery cover to prevent its exposure to moisture 5 When installing AC type faucets strictly f...

Страница 2: ...rs Under Counter Lavatory K 2661T Forefront Vessel K 14800T Chalice Vessel NOTE To prevent water from splashing out users are recommended to use lavatories as recommended above OPERATION INSTRUCTIONS...

Страница 3: ...more than 2 0L s at 0 3MPa Timeout Setting 1 minute OperationTemperature 1 55 Water Temperature 0 5 71 Water Pressure 0 05 0 86MPa 41 2 54 31 75 226 66 5 72 54 Output DC3V 3V Input AC220V 220V ROUGH I...

Страница 4: ...owed to enter or reflected into the sensing window where no objects susceptible to reflection are placed in front of the sensor e g mirror polished stainless steel and other objects with mirrored surf...

Страница 5: ...Make faucet water pipe and wire through mounting bracket screw and secure spout to the mounting bracket make sure the spout forwarding to vessel 3 Insert the escutcheon 3 into the spout and secure it...

Страница 6: ...fix the control box on the wall by screws 8 keep the control box parallel to the wall 5 6 7 10 11 1 2 3 12 13 2 5 14 13 12 Outlet Inlet 12 13 14 15 16 10 9 11 Round Hole Hex Hole Take out the battery...

Страница 7: ...tomatic adjusting sensing distance about 2minutes The faucet will not work during this period U 7 5 6 1 5 6 17 U 2 2 Connect AC DC transformer How to Install the Drain 18 19 18 19 Screw off the drain...

Страница 8: ...Connect to electrical Source AC220V DC Connect to Faucet Connect to electrical Source Connect to Faucet Note Not allowed connect AC 220V electrical source to DC wire connector of AC DC transformer Fa...

Страница 9: ...ove 2 After wire layout finished check and repair if needed Then connect AC connector of AC DC transformer to electrical source from the control box and DC connector of AC DC transformer to faucet Tur...

Страница 10: ...read check valve G1 2 MIN 50mm 10 1205259 2 A Wall Wall Tee hot Outlet Tee cold G1 2 Please user prepare external thread check valve G1 2 G1 2 Please user prepare external thread check valve G1 2 Tee...

Страница 11: ...faucet is in the period of adjusting sensing distance after power on for 2 minutes During these 2 minutes please do not put objects in the sensing range 2 The indicator flashes every 2 seconds As for...

Страница 12: ...27 3 Remove and clean the filters 25 then reinstall them 3 15 3 Intelligent Stopping Flowing Water will flow out when object are putted into the sensing range If the objects hold still for 15 seconds...

Страница 13: ...r 2 minutes Open the connector assemblies Check the batteries Check the power supply and the conncetion Remove the object Clean the sensing window Check the connector 2 1 No water flow Indicator not f...

Страница 14: ...5611 SP CP Drain 2 5mm Hex Wrench 2 5mm 1 5mm Hex Wrench 1 5mm 16306T NA AC DC Transformer Only for 98452T CP 98452T CP 1068120 SP Connection Wire Kit Battery Alkaline Largess 2013 2013 18 E 201206 14...

Отзывы: