将安装组件放入槽内,并用自攻

螺钉固定。

保证安装组件的底部与完工墙面的距

离在

70

105mm

之间,如图(Ⅰ)。

保证暗装架组件的底部与墙面平行,

不能歪斜,如图(Ⅱ)。

一 安装暗装架组件

根据台盆大小确定安装方式,确保

龙头出水中心正对台盆中心位置。

1.

凿挖安装槽坑

根据安装尺寸图确定安装位置,凿

出槽坑,埋设供水管,暂不供水。

槽深

70

105mm

,尺寸如图。安

装位置应避免光源直射或反射进入

感应窗口,不能在感应器正对面有

易反射的物品(如镜子、光亮不锈

钢件及其他镜面物体等);不能靠

近强烈紫外线或电磁场。

在安装尺寸位置钻孔,打入膨胀管。

2.

固定安装组件

1. Install Mounting Bracket Assy.

INSTALLATION

Determine installation method per 
lavatory size, and make sure the center 
of faucet outlet aligns with the center of 
the lavatory.

1. Chisel out a Slot

Determine the installation lacation per
rough-in. Chisel out a slot with a depth 
of 70~105mm and lay water supply 
hoses. Turn off the water supply 
temporarily. The dimensions are shown 
in the figure. The installation area shall 
be located at a place where no direct
light is allowed to enter or reflected into
the sensing window, where no objects
susceptible to reflection are placed in 
front of the sensor (e.g., mirror, polished 
stainless steel and other objects with 
mirrored surface); where no strong 
ultraviolet radiation or electromagnetia 
field is found nearby.

Drew mounting hole and put in 
expansion pipe.

2. Secure Mounting Bracket Assy.

Insert the mounting bracket assy. to the 
slot and secure it with self-tapping 
screws.

Ensure that the distance between the 
bottom of the mounting bracket and the 
wall ranges between 70~105mm as 
shown in Fig. (I).

Ensure that the bottom of the mounting 
bracket assy. is parallel with the wall as 
shown in Fig. (II).

150

58

22

90

80

80

完工墙面

70~105

4

Содержание LOURE 98452T-CP

Страница 1: ...When installing DC type faucets pay special attention to the directions of battery electrodes Tighten the battery cover to prevent its exposure to moisture 5 When installing AC type faucets strictly f...

Страница 2: ...rs Under Counter Lavatory K 2661T Forefront Vessel K 14800T Chalice Vessel NOTE To prevent water from splashing out users are recommended to use lavatories as recommended above OPERATION INSTRUCTIONS...

Страница 3: ...more than 2 0L s at 0 3MPa Timeout Setting 1 minute OperationTemperature 1 55 Water Temperature 0 5 71 Water Pressure 0 05 0 86MPa 41 2 54 31 75 226 66 5 72 54 Output DC3V 3V Input AC220V 220V ROUGH I...

Страница 4: ...owed to enter or reflected into the sensing window where no objects susceptible to reflection are placed in front of the sensor e g mirror polished stainless steel and other objects with mirrored surf...

Страница 5: ...Make faucet water pipe and wire through mounting bracket screw and secure spout to the mounting bracket make sure the spout forwarding to vessel 3 Insert the escutcheon 3 into the spout and secure it...

Страница 6: ...fix the control box on the wall by screws 8 keep the control box parallel to the wall 5 6 7 10 11 1 2 3 12 13 2 5 14 13 12 Outlet Inlet 12 13 14 15 16 10 9 11 Round Hole Hex Hole Take out the battery...

Страница 7: ...tomatic adjusting sensing distance about 2minutes The faucet will not work during this period U 7 5 6 1 5 6 17 U 2 2 Connect AC DC transformer How to Install the Drain 18 19 18 19 Screw off the drain...

Страница 8: ...Connect to electrical Source AC220V DC Connect to Faucet Connect to electrical Source Connect to Faucet Note Not allowed connect AC 220V electrical source to DC wire connector of AC DC transformer Fa...

Страница 9: ...ove 2 After wire layout finished check and repair if needed Then connect AC connector of AC DC transformer to electrical source from the control box and DC connector of AC DC transformer to faucet Tur...

Страница 10: ...read check valve G1 2 MIN 50mm 10 1205259 2 A Wall Wall Tee hot Outlet Tee cold G1 2 Please user prepare external thread check valve G1 2 G1 2 Please user prepare external thread check valve G1 2 Tee...

Страница 11: ...faucet is in the period of adjusting sensing distance after power on for 2 minutes During these 2 minutes please do not put objects in the sensing range 2 The indicator flashes every 2 seconds As for...

Страница 12: ...27 3 Remove and clean the filters 25 then reinstall them 3 15 3 Intelligent Stopping Flowing Water will flow out when object are putted into the sensing range If the objects hold still for 15 seconds...

Страница 13: ...r 2 minutes Open the connector assemblies Check the batteries Check the power supply and the conncetion Remove the object Clean the sensing window Check the connector 2 1 No water flow Indicator not f...

Страница 14: ...5611 SP CP Drain 2 5mm Hex Wrench 2 5mm 1 5mm Hex Wrench 1 5mm 16306T NA AC DC Transformer Only for 98452T CP 98452T CP 1068120 SP Connection Wire Kit Battery Alkaline Largess 2013 2013 18 E 201206 14...