Kohler LOURE 98452T-CP Скачать руководство пользователя страница 13

常见故障排除

以下部分故障现象可通过指示灯闪烁情况识别。(参考

感应指示灯的各种闪烁情况

   

    

    

 

  处理方法

无电池或电池装反

(

直流电

)

无电源或接线有误

(

交流电

)          

感应范围内有其它物体

     

感应窗口较脏
接线端未插好、插错

     

        

 

不出水

(感应指示灯不闪烁)

感应指示灯闪烁
不出水

  

感应指示灯闪烁

  

出水量小

 

1

分钟以内不止水

 

(感应指示灯不闪烁)

刚装机完毕
阀体组件或角阀关闭

 

过滤装置堵塞
节流器堵塞

          

阀体组件或角阀是否彻底打开

节流器堵塞
过滤装置堵塞
水压太低

                     

 

用内六角扳手逆时针旋转阀体组件
的调节螺栓或角阀
清洗节流器
清洗过滤装置
检查供水系统

 

等待

2

分钟

 

打开阀体组件或角阀

清洗过滤装置
清洗节流器

检查电池
检查总电源和接线情况
移开物体
清洁窗口
检查接线端

TROUBLE SHOOTING

Some trouble symptoms can be identified by the indicator's flashing. 

         Symptoms

Probable Causes

Corrective Action

No battery or wrongly connected 
No power supply or wrong connection
Object in sensing range
Dirt on the sensing window
The connector does not connect well

No water flow while 

the indicator flashes

Keep water out within 1 minute 

while indicator does not flash 

Just finishing installation
The connector assemblies are closed
The filter is blocked

The connector assemblies are not open 
completely

The filter is blocked
The supply water pressure is lower

Turn counterclockwise the adjustment bolts on 
connector assemblies with  the hex wrench

Clean filter
Check the water supply system

  Wait for 2 minutes
  Open the connector assemblies
  

Check the batteries
Check the power supply and the conncetion
Remove the object
Clean the sensing window
Check the connector

感应指示灯每

2

秒快速

闪烁

1

次而不出水

电池耗尽

(

直流电

)

刚刚停电

(

交流电

)

直流或交流接线端接触不良

(

交流电

)

更换电池
检查总电源
重新连接接插件

No water flow

(Indicator not flashing)

The indicator flashes once

every 2 seconds and the 

water  doesn't flow out.

Low water flow while the 

indicator does not flash

Object in sensing range 

Remove object

 

感应范围内有物体

 

移开物体

Refer to "Note of the Indicator Flashing"

如按以上操作仍未解除故障,请与销售商或科勒

(

中国

)

投资有限公司联系。

除安装更换电池外,请勿随意拆卸龙头其它部件。

Please contact with distributor or Kohler China Investment Co., Ltd., if the trouble remains after above-mentioned actions are taken.
Please do not disassembly the other parts of the faucet freely except installing and replacing batteries.

Batteries are out of power
Just power cut
DC or AC connector 

of AC/DC transformer

may not connect well

  Replace batteries
  Check the power supply
  Reconnect the connector

The regulator 

 is blocked

Clean 

regulator

The regulator 

 is blocked

Clean 

regulator

Clean filter

1205259-2-A

13

Содержание LOURE 98452T-CP

Страница 1: ...When installing DC type faucets pay special attention to the directions of battery electrodes Tighten the battery cover to prevent its exposure to moisture 5 When installing AC type faucets strictly f...

Страница 2: ...rs Under Counter Lavatory K 2661T Forefront Vessel K 14800T Chalice Vessel NOTE To prevent water from splashing out users are recommended to use lavatories as recommended above OPERATION INSTRUCTIONS...

Страница 3: ...more than 2 0L s at 0 3MPa Timeout Setting 1 minute OperationTemperature 1 55 Water Temperature 0 5 71 Water Pressure 0 05 0 86MPa 41 2 54 31 75 226 66 5 72 54 Output DC3V 3V Input AC220V 220V ROUGH I...

Страница 4: ...owed to enter or reflected into the sensing window where no objects susceptible to reflection are placed in front of the sensor e g mirror polished stainless steel and other objects with mirrored surf...

Страница 5: ...Make faucet water pipe and wire through mounting bracket screw and secure spout to the mounting bracket make sure the spout forwarding to vessel 3 Insert the escutcheon 3 into the spout and secure it...

Страница 6: ...fix the control box on the wall by screws 8 keep the control box parallel to the wall 5 6 7 10 11 1 2 3 12 13 2 5 14 13 12 Outlet Inlet 12 13 14 15 16 10 9 11 Round Hole Hex Hole Take out the battery...

Страница 7: ...tomatic adjusting sensing distance about 2minutes The faucet will not work during this period U 7 5 6 1 5 6 17 U 2 2 Connect AC DC transformer How to Install the Drain 18 19 18 19 Screw off the drain...

Страница 8: ...Connect to electrical Source AC220V DC Connect to Faucet Connect to electrical Source Connect to Faucet Note Not allowed connect AC 220V electrical source to DC wire connector of AC DC transformer Fa...

Страница 9: ...ove 2 After wire layout finished check and repair if needed Then connect AC connector of AC DC transformer to electrical source from the control box and DC connector of AC DC transformer to faucet Tur...

Страница 10: ...read check valve G1 2 MIN 50mm 10 1205259 2 A Wall Wall Tee hot Outlet Tee cold G1 2 Please user prepare external thread check valve G1 2 G1 2 Please user prepare external thread check valve G1 2 Tee...

Страница 11: ...faucet is in the period of adjusting sensing distance after power on for 2 minutes During these 2 minutes please do not put objects in the sensing range 2 The indicator flashes every 2 seconds As for...

Страница 12: ...27 3 Remove and clean the filters 25 then reinstall them 3 15 3 Intelligent Stopping Flowing Water will flow out when object are putted into the sensing range If the objects hold still for 15 seconds...

Страница 13: ...r 2 minutes Open the connector assemblies Check the batteries Check the power supply and the conncetion Remove the object Clean the sensing window Check the connector 2 1 No water flow Indicator not f...

Страница 14: ...5611 SP CP Drain 2 5mm Hex Wrench 2 5mm 1 5mm Hex Wrench 1 5mm 16306T NA AC DC Transformer Only for 98452T CP 98452T CP 1068120 SP Connection Wire Kit Battery Alkaline Largess 2013 2013 18 E 201206 14...

Отзывы: