Kohler LOURE 98452T-CP Скачать руководство пользователя страница 6

将角阀

(9)

与管道出水口连接,再

将软管

(10)

与角阀

(9)

连接,在软

(10)

前放一水桶,将角阀

(9)

全打开,打开供水系统,通水约一

分钟,确认管道连接触无渗漏后,

关闭供水系统。

10

Connect check valve (9) and outlet 

together, then connect the hose (10) and 

check valve (9). Put a bucket in the front 

of hose (10), turn on the check valve (9)

completely and open the water supply. 

After the water flushing about 1 minute, 

make sure no leakage and turn off the 

water supply. 

4.

用螺丝刀拧下阀盒盖螺钉

(7)

,将

阀盒盖

(6)

打开。根据安装尺寸图

确定控制阀组件

(5)

安装位置,打

孔,打入膨胀管,使阀盒紧贴墙

面且控制阀组件出水口朝上,再

用膨胀螺钉

(8)

将控制阀组件固定

在墙壁上,注意控制阀组件要与

墙面保持平行。

控制阀组件的安装固定

4. Fix the control box

Remove the cover (6) after loose the 

screws (7). Determine the installation 

location of control box (5) per rough-in, 

then drill holes and place sheath in it. 

Make the control box cling on the wall 

and outlet upturned, then fix the control

box on the wall by screws (8), keep the 

control box parallel to the wall.

5

6

7

再将软管

(10)

与阀体进水口连接,

然后连接阀体出水口与龙头组件

出水软管

(11)

注意:

1.

出水软管处的平垫不要遗漏。

2.

3.请勿将进水口与出水混淆。

取出电池盒组件,拧开螺钉

(12)

按电池盒盖

(13)

上的正负极标示分

别装入

2

5

号电池

(14)

,锁紧电池

盒盖

(13)

的螺钉

(12)

后,将电池盒

组件放入阀盒的专用槽内。

注意:

电池正负极不能装反,新旧电池不

能混用。

出水口

Outlet

进水口

Inlet

12

13

14

15

16

10

9

11

圆孔

Round Hole

六角形孔

Hex Hole

Take out the battery box and loose the 

screws (12), place two “AA” batteries into 

the box according to the negative and 

positive pole mark on the cover of battery 

box (13). Put the box in the particular 

groove in the valve box after tight the 

screws.

Note:

Do not mistake the pole and mixture the 

new and used batteries.

8

8

6

1205259-2-A

请用户自备角阀。

Connect hose (10) to the inlet of valve, 

then connect the outlet of valve and

inlet (11) of spout assy.

Note:

1.

3. Do not confuse the inlet and outlet.

2.

by themselves.

Do not lost the washer of hose.

Please let user prepare check valve

9

9

Содержание LOURE 98452T-CP

Страница 1: ...When installing DC type faucets pay special attention to the directions of battery electrodes Tighten the battery cover to prevent its exposure to moisture 5 When installing AC type faucets strictly f...

Страница 2: ...rs Under Counter Lavatory K 2661T Forefront Vessel K 14800T Chalice Vessel NOTE To prevent water from splashing out users are recommended to use lavatories as recommended above OPERATION INSTRUCTIONS...

Страница 3: ...more than 2 0L s at 0 3MPa Timeout Setting 1 minute OperationTemperature 1 55 Water Temperature 0 5 71 Water Pressure 0 05 0 86MPa 41 2 54 31 75 226 66 5 72 54 Output DC3V 3V Input AC220V 220V ROUGH I...

Страница 4: ...owed to enter or reflected into the sensing window where no objects susceptible to reflection are placed in front of the sensor e g mirror polished stainless steel and other objects with mirrored surf...

Страница 5: ...Make faucet water pipe and wire through mounting bracket screw and secure spout to the mounting bracket make sure the spout forwarding to vessel 3 Insert the escutcheon 3 into the spout and secure it...

Страница 6: ...fix the control box on the wall by screws 8 keep the control box parallel to the wall 5 6 7 10 11 1 2 3 12 13 2 5 14 13 12 Outlet Inlet 12 13 14 15 16 10 9 11 Round Hole Hex Hole Take out the battery...

Страница 7: ...tomatic adjusting sensing distance about 2minutes The faucet will not work during this period U 7 5 6 1 5 6 17 U 2 2 Connect AC DC transformer How to Install the Drain 18 19 18 19 Screw off the drain...

Страница 8: ...Connect to electrical Source AC220V DC Connect to Faucet Connect to electrical Source Connect to Faucet Note Not allowed connect AC 220V electrical source to DC wire connector of AC DC transformer Fa...

Страница 9: ...ove 2 After wire layout finished check and repair if needed Then connect AC connector of AC DC transformer to electrical source from the control box and DC connector of AC DC transformer to faucet Tur...

Страница 10: ...read check valve G1 2 MIN 50mm 10 1205259 2 A Wall Wall Tee hot Outlet Tee cold G1 2 Please user prepare external thread check valve G1 2 G1 2 Please user prepare external thread check valve G1 2 Tee...

Страница 11: ...faucet is in the period of adjusting sensing distance after power on for 2 minutes During these 2 minutes please do not put objects in the sensing range 2 The indicator flashes every 2 seconds As for...

Страница 12: ...27 3 Remove and clean the filters 25 then reinstall them 3 15 3 Intelligent Stopping Flowing Water will flow out when object are putted into the sensing range If the objects hold still for 15 seconds...

Страница 13: ...r 2 minutes Open the connector assemblies Check the batteries Check the power supply and the conncetion Remove the object Clean the sensing window Check the connector 2 1 No water flow Indicator not f...

Страница 14: ...5611 SP CP Drain 2 5mm Hex Wrench 2 5mm 1 5mm Hex Wrench 1 5mm 16306T NA AC DC Transformer Only for 98452T CP 98452T CP 1068120 SP Connection Wire Kit Battery Alkaline Largess 2013 2013 18 E 201206 14...

Отзывы: