Repair
Service and Repair Manual
Fuel system
Removal
u
Remove screws
5
and break leakage detection block
6
.
u
Remove screws
4
and retaining plate
3
.
u
Remove screws
2
and fuel return block
1
.
Installation
u
Mount fuel return block
1
with screws
2
.
u
Mount retaining plate
3
with screws
4
.
u
Mount break leakage detection block
6
with screws
5
.
u
Tighten screws
2, 4, 5
to torque.
Specific values
Not applicable.
Tightening specifications
Refer to standard tightening torques.
(For more information see: 5.3 Standard tightening torques,
3.6.7 Fuel pump HP and LP removal and installation (SL 250)
Previous tasks
q
Close fuel supply.
q
Release the pressure of the HP fuel system using Kodia tools.
q
Remove fuel pipings connected to HP fuel pump.
Specific safety instructions
NOTICE
Risk of property damage by reuse of sealing.
Leakage by faulty seal.
u
Replace all sealings.
Special tools
Special tool
Designation
HP Fuel Pump Lifting Device
134
© 2021 by Kohler Co. All rights reserved.
KD83V16 33525088901_2_1 EN_US