Service and Repair Manual
Repair
Driving gear
Information
Use the turning device to rotate the crankshaft.
(For more information see: 4.1.2 Turning device,
u
Remove the cap from one end of the sample container.
Information
Place the sample container cap in a safe place.
u
Make sure that the lower sample opening
2
is clean and free from dirt, grease, and engine oil.
u
Remove the plug from the lower sample opening
2
.
u
Immediately install the sample container into the lower sample opening
2
.
u
Tighten the sample container by hand, then loosen it by one turn.
Information
Do not use any tool to tighten the sample container.
u
Remove the cap from the other end of the sample container.
Information
Place the sample container cap in a safe place.
u
Make sure that silicon oil flows from the torsional vibration damper into the sample container.
Information
If the flow of silicon oil is very slow, open the upper sample opening
1
.
u
When the sample container is 75% full, install a cap on the end of the sample container.
u
Tighten the sample container cap by hand.
Information
Do not use any tool to tighten the sample container cap.
u
Install a new screw plug into the upper sample opening
1
if it has been opened.
Information
Always replace the screw plug.
u
Tighten the screw plug to torque.
(For more information see: Tightening specifications,
u
Remove the sample container from the lower sample opening
3
.
Information
Make sure that silicon oil does not leak from the sample container.
KD83V16 33525088901_2_1 EN_US
2021-07
© 2021 by Kohler Co. All rights reserved.
107