Repair
Service and Repair Manual
Electrical system
u
Remove screws
4
.
u
Remove starter
2
.
Installation
u
Position starter
2
.
u
Tighten screws
4
.
u
Connect plug
3
.
u
Connect power supply
5
with nut.
u
Tighten nut to torque.
u
Connect ground cable
6
with nut and tighten according to tightening specifications.
Specific values
Not applicable.
Tightening specifications
Fig. 286: Starter nuts
Reference
Key
Screw specifications
Lubricant *
Reuse**
Torque
Angle (°)
Step
± 5%
Step
± 5°
1
-
M12
-
Yes
1 22 Nm
(16 ft-lb)-
30 Nm
(22 ft-lb)
-
-
2
-
M12
-
Yes
1 22 Nm
(16 ft-lb)-
30 Nm
(22 ft-lb)
-
-
Tab. 55: Tightening specifications table
*Lubricants:
MG = Molykote G-n-plus
MW = Castrol Optimol paste white T
MH = Molykote HSC
O = Engine oil
250
© 2021 by Kohler Co. All rights reserved.
KD83V16 33525088901_2_1 EN_US