TP-6137 5/03
38
Section 7 Troubleshooting
Problem
Possible Cause
Corrective Action
Stops suddenly
Out of fuel.
Replenish fuel supply.
Air intake clogged.
Service the air intake screen.
Circuit breaker tripped in the controller.
Reset the circuit breaker.
Inoperative seawater pump impeller.
Replace the impeller.
Clogged seawater strainer.
Clean the strainer.
Fuel line restricted.
Check the fuel lines and the fuel tank.
Dirty fuel filter.
Clean the fuel filter.
No/low oil pressure.
Check the oil pressure and pump.
High temperature.
Check the engine cooling system.
Inoperative high exhaust temperature
(HET), low oil pressure (LOP), and/or high
water temperature (HWT) shutdown
switch(es).
Check the HET, LOP, and HWT shutdown
switch(es).
Loss of AC output.
Contact your local Kohler generator set
distributor for service.
Operates erratically
Air intake clogged.
Service the air intake screen.
Stale or bad fuel.
Replace the fuel.
Clogged fuel filter.
Service the fuel filter.
Vent in fuel tank cap obstructed.
Clean the cap in solvent; blow dry.
Water, dirt, or air in the fuel system.
Drain, flush, fill, and bleed air in the
system.
Dirty or faulty injectors.
Contact your local Kohler generator set
distributor for service.
Faulty governor link.
Contact your local Kohler generator set
distributor for service.
Inoperative fuel feed pump.
Replace the fuel feed pump.
Incorrect valve clearance.
Contact your local Kohler generator set
distributor for service.
Inoperative valve spring.
Contact your local Kohler generator set
distributor for service.
Incorrect compression.
Contact your local Kohler generator set
distributor for service.
Engine knocks
Improper fuel type.
Use proper fuel type; consult fuel supplier.
Improper fuel injection timing.
Contact your local Kohler generator set
distributor for service.
Improper cylinder top clearance.
Contact your local Kohler generator set
distributor for service.
Inoperative piston or piston ring.
Contact your local Kohler generator set
distributor for service.
Inoperative crankshaft bearing or piston
pin bearing.
Contact your local Kohler generator set
distributor for service.
Improper valve clearance piston pin
bearing.
Contact your local Kohler generator set
distributor for service.
Air in injectors.
Bleed air.
Loses power
Air intake clogged.
Service the air intake screen.
Bad or stale fuel.
Replace the fuel.
Engine not operating at rated RPM.
Check the governor.
Governor adjustments incorrect.
Adjust the governor.
Содержание 3.5EFOZ
Страница 1: ...Marine Generator Sets Includes Engine Maintenance Models 4EOZ 3 5EFOZ TP 6137 5 03 Service ...
Страница 10: ...TP 6137 5 03 VI Safety Precautions and Instructions Notes ...
Страница 12: ...TP 6137 5 03 ii Service Assistance Notes ...
Страница 28: ...TP 6137 5 03 16 Section 3 Scheduled Maintenance Notes ...
Страница 42: ...TP 6137 5 03 30 Section 5 Fuel System Notes ...
Страница 48: ...TP 6137 5 03 36 Section 6 Cooling System Notes ...
Страница 102: ...TP 6137 5 03 90 Section 10 Generator and Engine Disassembly Reassembly Notes ...
Страница 104: ...TP 6137 5 03 92 Section 11 Wiring Diagrams 11 1 Wiring Diagram Schematic GM20645 B ...
Страница 105: ...TP 6137 5 03 93 Section 11 Wiring Diagrams 11 2 Wiring Diagram Point to Point GM20645 B ...
Страница 106: ...TP 6137 5 03 94 Section 11 Wiring Diagrams Notes ...
Страница 114: ......
Страница 115: ......