49
Section 8 Controller Troubleshooting
Yes
B
D
LOP—Check the oil level,
the oil pressure, and the
alarm switch.
D
HET and HCHT—Check if
water flows out of the
exhaust manifold and if the
two alarm switches work.
D
Are these checks okay?
No
Can you stop the engine
using the on/off switch?
Change the control panel.
Yes
After the start switch is
release, is the engine
operating?
No
Is 12 DC voltage present on
the K2 relay coil?
No
Is any red LEDs (LOP, HET,
HCHT) lit?
No
Change the control panel.
Generator set checks out
okay.
No
Are the 30-87 terminals of
the K2 relay open?
Change the K2 relay.
Yes
Yes
Figure 8-8
Troubleshooting Relay Controller Control Panel (3 of 4)
Содержание 3.5EFOZ
Страница 1: ...Marine Generator Sets Includes Engine Maintenance Models 4EOZ 3 5EFOZ TP 6137 5 03 Service ...
Страница 10: ...TP 6137 5 03 VI Safety Precautions and Instructions Notes ...
Страница 12: ...TP 6137 5 03 ii Service Assistance Notes ...
Страница 28: ...TP 6137 5 03 16 Section 3 Scheduled Maintenance Notes ...
Страница 42: ...TP 6137 5 03 30 Section 5 Fuel System Notes ...
Страница 48: ...TP 6137 5 03 36 Section 6 Cooling System Notes ...
Страница 102: ...TP 6137 5 03 90 Section 10 Generator and Engine Disassembly Reassembly Notes ...
Страница 104: ...TP 6137 5 03 92 Section 11 Wiring Diagrams 11 1 Wiring Diagram Schematic GM20645 B ...
Страница 105: ...TP 6137 5 03 93 Section 11 Wiring Diagrams 11 2 Wiring Diagram Point to Point GM20645 B ...
Страница 106: ...TP 6137 5 03 94 Section 11 Wiring Diagrams Notes ...
Страница 114: ......
Страница 115: ......