Section 2 Scheduled Maintenance
2.3 Spark Plugs
Reset the spark plug gap or replace the plugs with new
plugs as necessary.
Spark Plug Maintenance Procedure
1. Clean the area around the base of the spark plug to
keep dirt and debris out of the engine.
2. Remove the spark plug and check its condition.
Replace the spark plug if it is worn or if its reuse is
questionable.
3. Check the spark plug gap using a wire feeler
gauge. Adjust the gap to 0.76 mm (0.030 in.) by
carefully bending the ground electrode.
See
Figure 2-6 and Figure 2-7.
Figure 2-6
Checking the Spark Plug Gap
Figure 2-7
Adjusting the Spark Plug Gap
2.4 Air Cleaner Element and
Precleaner
The engine has a replaceable high-density paper air
cleaner element with an oiled foam precleaner. See
Figure 2-8. Refer to Section 1.6, Service Views, for the
air cleaner location.
Wash and oil the precleaner and replace the paper
element at the intervals shown in the service schedule.
Service the air cleaner more often if the generator set
operates under dusty or dirty conditions.
Refer to
Maintenance and Service Parts in the Introduction
section of this manual for replacement part numbers.
Keep the area around the air cleaner housing free of dirt
and debris.
Note:
Operating the engine with loose or damaged air
cleaner components could allow unfiltered air
into the engine, causing premature wear and
failure.
Air Cleaner Service Procedure
1. Disable the generator set.
a. Place the generator set master switch in the
OFF/RESET position.
b. Disconnect the power to the battery charger, if
equipped.
c. Disconnect the generator set engine starting
battery, negative (--) lead first.
2. Remove the foam precleaner and paper element.
a. Loosen the air cleaner cover retaining knob and
remove the cover.
b. Remove the element cover nut, element cover,
and paper element with precleaner.
c. Remove the precleaner from the paper
element.
1
2
3
4
5
6
7
586536
1. Cover knob
2. Air cleaner cover
3. Element cover nut
4. Element cover
5. Foam precleaner
6. Air cleaner element
7. Air cleaner base
Figure 2-8
Air Cleaner Components
Содержание 11RMY
Страница 1: ...Industrial Generator Sets Models 8 5RMY 11RMY Controllers Relay TP 5867 11 02d Service...
Страница 16: ...TP 5867 11 02 6 Section 1 Specifications Notes...
Страница 32: ...TP 5867 11 02 22 Section 3 Troubleshooting Notes...
Страница 40: ...TP 5867 11 02 30 Section 4 Controller Troubleshooting Notes...
Страница 44: ...TP 5867 11 02 34 Section 5 Generator Relay Controller Troubleshooting Notes...
Страница 68: ...TP 5867 11 02 58 Section 6 Component Testing and Adjustment Notes...
Страница 72: ...TP 5867 11 02 62 Section 7 Generator Reconnection Notes...
Страница 80: ...TP 5867 11 02 70 Section 8 Disassembly Reassembly Notes...
Страница 82: ...TP 5867 11 02 72 Section 9 Wiring Diagrams Notes...
Страница 83: ...TP 5867 11 02 73 Section 9 Diagrams and Drawings Relay Controller Schematic Diagram 1 Phase ADV 6297 B...
Страница 85: ...TP 5867 11 02 75 Section 9 Diagrams and Drawings Relay Controller Schematic Diagram 1 Phase ADV 6297 E...
Страница 87: ...TP 5867 11 02 77 Section 9 Diagrams and Drawings Relay Controller Schematic Diagram ADV 6524...
Страница 88: ...TP 5867 11 02 78 Section 9 Diagrams and Drawings 6 Relay Controller Point to Point Wiring Diagram GM10619...
Страница 96: ......
Страница 97: ......