Chapter 3 Installation method
MDC-5200/5500 Series
3-40
0092655002-03
3.4.4 Connecting a Gyro converter unit or THD
Figure 3.21 Cable connection of Display unit to Gyro converter unit or THD
Connect GPS converter or THD signal to one of the J3, J5 or J6 port.
Set the baud rate of connected port to 38400 bps (61162-2) in [MAINTENANCE] => [I/O]
menu.
Set the output of Gyro converter and THD (gyro serial output) as follows.
Baud rate: 38400bps
TX cycle: 25ms - 50ms,
Sentence: THS or HDT,
Please refer to the operation manual of each unit for details.
Gyro synchro or step signal
THD
OR
J3
Gyro converter
(Option item: ADPC-101)
Serial signal
IEC 61162-2