MAN mode
(1) Check MAN indication of GAIN mode from upper right of the display. If GAIN mode is AUTO,
change to MAN mode. If SEA mode is AUTO, change to MAN mode. If RAIN mode is CFAR,
change to MAN mode.
(2) Set the range scale at 24 NM, set SEA at 0 by turning SEA knob, set RAIN at 0 by turning RAIN
knob, set PICTURE 1 mode, set GAIN at 0 by turning GAIN knob and set BRILL at a maximum
level by turning BRILL knob.
(3) Press MENU
key to display “Menu”.
Select [MAINTENANCE] => [PRESET] => [GAIN MIN] and highlight of the last digit of entry frame
of numerical value by moving the trackball/joystick.
(4) Move the trackball/joystick up and down to change the value, only the highest signal levels are
presented. Press ENT key for setting.
Setting value is 0 to 4095
AUTO mode
(1) Check AUTO indication of GAIN mode from upper right of the display. If GAIN mode is MAN,
change to AUTO mode. If SEA mode is AUTO, change to MAN mode. If RAIN mode is CFAR,
change to MAN mode.
(2) Set the range scale at 24 NM, set SEA at 0 by turning SEA knob, set RAIN at 0 by turning RAIN
knob, set PICTURE 1 mode, set GAIN at 0 by turning GAIN knob and set BRILL at a maximum
level by turning BRILL knob.
(3) Press MENU
key to display “Menu”.
Select [MAINTENANCE] => [PRESET] => [GAIN MIN] and highlight of the last digit of entry frame
of numerical value by moving the trackball/joystick.
(4) Move the trackball/joystick up and down to change the value, only the highest signal levels are
presented. Press ENT key for setting.
Setting value is 0 to 4095
4.4.3.2 GAIN MAX (MAN and AUTO mode)
This setting is a function to make the value set under GAIN sensitivity control effective even when GAIN
is set at a maximum level by turning GAIN knob.
MAN mode
(1) Check MAN indication of GAIN mode from upper right of the display. If GAIN mode is AUTO,
change to MAN mode. If SEA mode is AUTO, change to MAN mode. If RAIN mode is CFAR,
change to MAN mode.
Содержание MDC-5204
Страница 1: ......
Страница 2: ......
Страница 26: ...Chapter 3 Installation method MDC 5200 5500 Series 3 2 0092655002 03 RB808 RB809 Unit mm inch ...
Страница 51: ...MDC 5200 5500 Series Chapter 3 Installation method 0092655002 03 3 27 MRO 108 MDC 5500 series Unit mm inch ...
Страница 70: ... This page intentionally left blank ...
Страница 154: ... This page intentionally left blank ...
Страница 174: ... This page intentionally left blank ...
Страница 175: ...0092655002 03 A 1 INTER CONNECTION DIAGRAM RB806 ...
Страница 176: ...A 2 0092655002 03 INTER CONNECTION DIAGRAM RB807 ...
Страница 177: ...0092655002 03 A 3 INTER CONNECTION DIAGRAM RB808 ...
Страница 178: ...A 4 0092655002 03 INTER CONNECTION DIAGRAM RB809 ...
Страница 179: ...0092655002 03 A 5 INTER CONNECTION DIAGRAM MRD 109 MRO 108 ...
Страница 180: ...A 6 0092655002 03 INTER CONNECTION DIAGRAM MRD 111 ...
Страница 181: ......
Страница 182: ......