MDC-2200/2500 Series
Chapter 1 Preface
0093125002-04
1-5
1.5 In case no Heading and Speed signals are input from
navigation equipment
When no Heading and Speed signals are input from navigation equipment (in case not connected), this
radar gives alarms and warning messages on the screen, if the radar is started up by factory default
settings.
These alarms are disengaged by pressing “OFF” key temporarily, however, the alarms are activated
again next time the radar is started up.
Disengage the alarm detection function on start up by the following setting. Once set, the alarm is not
detected next time the radar is started up.
MENU => DATADISP => PROTECT CANCEL => ENT
MENU => NAV => STAB => GND => SEA => ENT
NAV => VECTOR TRUE/REL => TRUE => REL => ENT
I/O => HDG => HDG => ON => OFF => ENT
I/O => SPD => SPD => ON => OFF => ENT