CVR–010
Making Settings via System Menu
66
9.6. Selecting Menu Languages
Figure 9-6 Selecting Menu Languages – Example
・
Selecting option “
5:LANGUAGE
” displays the
languages that you can select to indicate various
options in the menu system.
・
The current software version supports English and
Russian, as in the example at right. Other
languages may be added in later versions.
Initially English is selected as the menu language.
・
If you wish to display the menu options in Russian
(or other available language)
, proceed via the
following steps:
(1) Select option “
5:LANGUAGE
” by pressing
(numeric key “
5
”)
.
(2) Highlight the desired option by pressing the appropriate numeric key.
(3) Press
to complete the selection. The
SYSTEM MENU
should then return.
(4) Press
to return to the normal echogram screen, unless you wish to make additional
settings on the
SYSTEM MENU
.
9.7. Selecting Alarm Handling Protocols
Figure 9-7
Selecting Alarm Handling Protocols
・
Selecting option "
6:BAM PROTOCOL
" displays the
associated submenu showing the following two types
of alarm handling procedure.
-
1:ALR , ACK
TYPE
: Optional setting, compliant with
IEC 61162–1 Ed. 4 standard
-
2:ALF, ACN
TYPE
: Initial setting, compliant with
IEC 61162–1 Ed. 5 standard
・
・
Option "
2:ALF, ACN TYPE
"
is initially selected.
Check the alarm handling protocol used in the INS
BAM (bridge al
ert
management) system of your
vessel, and select the correct one via the following
steps:
(1) Select option “
6:BAM PROTOCOL
” by pressing
(numeric key “
6
”)
.
(2) Highlight the desired option by pressing the appropriate numeric key.
(3) Press
to complete the selection. The
SYSTEM MENU
should then return.
(4) Press
to return to the normal echogram screen, unless you wish to make additional
settings on the
SYSTEM MENU
.
< WARNING >
USE OF THE WRONG PROTOCOL WILL MAKE IT IMPOSSIBLE FOR YOUR INS
APPLICATIONS TO REMOTELY CONFIRM THE ALARM STATUS, ACKNOWLEDGE
THE ACTIVE ALARM(S) AND/OR SILENCE THE ALARM SOUND.
< CAUTION >
Resetting the system will return the protocol setting to the
"
ALF, ACN TYPE
."
Be sure
to select the "ALR, ACK TYPE" if your BAM employs the IEC 61162–1 Ed. 4 protocol.
SYSTEM MENU
1:BACKGROUND
2:SYSTEM CHECK
3:OUTPUT STORED DATA
4:OUTPUT INTERVAL
5:LANGUAGE
6:BAM PROTOCOL
7:AUTO TVG RESPONSE
5:LANGUAGE
1:ENGLISH
2:RUSSIAN
SYSTEM MENU
1:BACKGROUND
2:SYSTEM CHECK
3:OUTPUT STORED DATA
4:OUTPUT INTERVAL
5:LANGUAGE
6:BAM PROTOCOL
7:AUTO TVG RESPONSE
6:BAM PROTOCOL
1
:
ALR, ACK TYPE