CVR–010
Basic Operating Instructions
(continued on next page)
20
7.2.
Control Panel Functions
(continued – 2/7)
②
Depth Range Key
Figure 7-7
Indication of Activating Range Selection Function – Example
・
Pressing this key activates the function of
depth range selection, highlighting the
lower range limit calibration, like the
example at right.
.
・
To select a desired range, press
(for
greater ranges) or
(for smaller
ranges).
・
When a menu is open, this key acts as
numeric key “
1
” to enter value
1
or to
select menu option 1.
③
Transducer Draft Key
・
To read depth from the surface or from the keel, the appropriate transducer draft value
(i.e. the distance between the waterline and the transducer face)
has to be entered.
・
The draft is initially set at 0.0 meter (
D F T = 0 . 0
)
.
Figure 7-8 On–Screen Operating Parameter Indications – Example
・
Pressing this key activates the
function of entering the transducer
draft.
・
The legend “
D F T= 0 . 0
” just below
the upper screen edge will be
highlighted, like the example at
right.
- To enter the draft, press
/
.
- To exit the mode, press
again.
・
When a menu is being opened,
this key acts as numeric key “
3
” to
enter value
3
or to select menu
option 3.
④
Up
Key
・
On normal echogram screen with no menu opened, pressing this key will result in an
operational error, causing the unit to beep three times in quick succession.
・
When the variable range marker (
VRM
)
is turned on, pressing this key moves the
marker upward (i.e. in the shallowing direction).
・
When a menu with two or more options is being opened, pressing this key selects those
options downward.
- To finalize selection, press
.
・
When selecting the depth ranges (
②
), pressing this key selects smaller ranges.
16m
12m
i
20m
Range selection
function activated
T
ransducer Draft
Control Mode