CVR–010
Basic Operating Instructions
37
7.8.2. Acknowledging Active Alarms
(2/3)
7.8.2.2. Remote Acknowledgement by Software Commands
(2/3)
7.8.2.2.1. Selecting Alarm Handling Protocols
・
Regarding alarm handling on the bridge, two IEC standard–based protocols are
selectable:
- Protocol based on IEC 61162–1 Ed. 5 (2016), initial setting
- Protocol based on IEC 61162–1 Ed. 4 (2010), user–selected optional setting
・
If your vessel's bridge al
ert
management (BAM) system employs the alarm handling
procedure compatible with the IEC 6162–1 Ed. 4 standard, select the matched standard
through the special menu termed "
SYSTEM MENU
," as summarized below.
(1) Turn off the equipment first, if it is already turned on.
(2) Display
the
SYSTEM MENU
by turning the unit on while holding down
or
.
(3) Select menu option "
6:BAM PROTOCOL
" by pressing
(numeric key “
6
”)
.
Figure 7-27
Selecting IEC 61162–1 Ed. 4 Standard
・
The following two options will be displayed:
-
1:ALR , ACK
TYPE
: Optional setting , compliant w it h
protocol std. IEC 61162–1 Ed. 4
-
2:ALF, ACN
TYPE
: Initial setting, compliant with
protocol std. IEC 61162–1 Ed. 5
・
Press
, selecting option "
1:ALR, ACK TYPE
."
(4) Press
to complete the selection..
(5) Press
to return to the normal echogram screen.
・
For other settings to be made on the
SYSTEM MENU
,
refer to Section 9 (Making Settings via SYSTEM MENU).
< WARNING >
USE OF THE WRONG PROTOCOL WILL MAKE IT IMPOSSIBLE FOR YOUR INS/BAM
APPLICATIONS TO REMOTELY CONFIRM THE ALARM STATUS, ACKNOWLEDGE
THE ACTIVE ALARM(S) AND/OR SILENCE THE ALARM SOUND.
7.8.2.2.2. Alarm
Acknowledgement
Using IEC 61162–1 Ed. 4 Format Commands
・
Initially the alarm handling procedure is set to the IEC 61162–1 Ed. 5 protocol (menu
option
ALF
,
ACN TYPE
on
BAM PROTOCOL
submenu in Figure 7-27 above).
・
Select the option
ALM, ACK TYPE
first.
・
To acknowledge an active alarm from your INS/BAM terminal, enter the following format
(IEC 61162–1 Ed. 4/NMEA–0183)
commands:
-
$
_ _ ACK
,
001
,
*
hh < CR > < LF> for depth alarm
-
$
_ _ ACK
,
002
,
*
hh < CR > < LF> for bottom–missing alarm
*
1
-
$
_ _ ACK
,
003
,
*
hh < CR > < LF> for power failure/low voltage alarm
・
Refer to paragraph 13.3.4.5 for detailed information on the alarm outputs.
*
1
:
Initially disabled; refer to paragraph 8.12 for details. This alarm function is not available when the BAM
communications protocol is set to the lEC 61162–1 Ed. 5 standard.
SYSTEM MENU
1:BACKGROUND
2:SYSTEM CHECK
3:OUTPUT STORED DATA
4:OUTPUT INTERVAL
5:LANGUAGE
6:BAM PROTOCOL
7:AUTO TVG RESPONSE
6:BAM PROTOCOL
1:ALR, ACK TYPE
2:ALF, ACN TYPE
Содержание CVR-010