CVR–010
Recommended Spare Parts
102
14.
Recommended Spare Parts
・
A list of the spare parts recommended for the maintenance and servicing for three to
five years is given below.
・
Replacing parts should be done by your dealer or a qualified service engineer.
・
The part numbers of PCB’s to be delivered may slightly change depending on the
production lot; however, spare PCB’s will be plug–for–plug compatible with the existing
ones in the unit.
< CAUTION >
There are no user serviceable parts inside the display cabinet. The user should
not open the cabinet for inspection, replacing suspected parts, or attempting to
change the alignments/hardware settings.
Table 14-1 Recommended Spare Parts
Part Name
Part Number
Quantity
・
Fuses
- for 12V DC operation:
3A/5.2X20mm
2
- for 24V / 32V DC operation:
2A/5.2X20mm
2
・
Connector Plugs
-
POWER
Plug:
CP111–3P
1
-
TRANSDUCER
Plug:
HS21P–3
-
I/O
Plug
*
1
:
CP111–8P
1
-
RS–422 – A/B
Plug
*
1
:
HDEB–9S
1
-
ALARM ACK
Plug
*
1
:
CP111–2P
1
-
ALARM OUT
Plug
*
1
:
CP111–6P
1
・
Power Cord (terminated in mating plug): M402–PW01
1
・
Printed Circuit Boards ( PCBs )
- Transceiver
PCB
*
2
(50 kHz):
M815–T50
1
- Transceiver
PCB
*
2
(200 kHz):
M815–T200
-
*
Main PCB:
M815–MAIN–B
*
3
1
- Key
PCB:
M815–KEY–A
*
3
1
・
TFT–LCD Module ( LCD panel):
LQ057AC111
1
*
1
:
Not needed unless these connections are used
for your installation.
*
2
:
Specify the transducer frequency of your installation when ordering. These boards are designed to match the
specified TOKIN transducers only.
*
3
:
Production lot number ; subject to change
Содержание CVR-010
Страница 1: ......
Страница 2: ......
Страница 4: ... This page intentionally left blank ...
Страница 10: ... This page intentionally left blank ...
Страница 113: ......
Страница 114: ......