A-61916 August 2019
51
Cleaning procedures
Cleaning your scanner and performing preventative maintenance on a regular
basis is required to ensure the best possible image quality.
Some document types generate more paper dust and debris and may require
more frequent cleaning.
Before cleaning your scanner or replacing consumables, review the following
information:
•
Some debris from the rubber tires on the feed module and separation roller
is normal. Tire debris does not always mean that the tires are worn or
damaged. After cleaning, inspect the tires for wear and replace the
separation roller, feed module or tires if necessary.
•
When cleaning rollers/tires, allow the rollers/tires to dry completely before
scanning.
•
Use only the recommended cleaning supplies. Using unapproved cleaning
fluids or solvents may damage the rubber tires.
•
Do not use cleaners in confined areas, use with adequate ventilation.
•
Do not use cleaners on hot surfaces. Allow surfaces to cool to ambient
temperature before cleaning.
•
Do not use canned/compressed air. Use of compressed air may cause
dust to be forced into the scanner’s imaging system and lodge in an area
that causes image quality issues and cannot be cleaned without Kodak
Alaris Service personnel.
•
Do not use flammable compressed aerosols on or around the scanner.
•
In addition to the recommended cleaning supplies, you may use a vacuum
cleaner to remove debris from the scanner.
•
Do not allow any cleaning fluids to get into the Ultrasonic Sensors, see
“Inside View” on page 6. If there is dust on the sensors, gently vacuum the
sensors and surrounding area.
•
Staticide wipes contain isopropanol which can cause eye irritation and dry
skin. Wash your hands with soap and water after performing maintenance
procedures. Refer to the Safety Data Sheet (SDS) for more information.
The SDS is available on the Kodak Alaris website at
NOTE:
To access the SDS, you will need to provide the catalog number
of the supply. See “Supplies and consumables” on page 60 for a
link to the catalog.
Vacuuming the output tray,
input elevator and
transport area
1. Power down the scanner.
2. Thoroughly vacuum the output tray and input tray areas.
3. Open the scanner cover.
4. Thoroughly vacuum the transport area.
Содержание S2000f Series