Spec Sheet
Burner System Loader System
PYROMAT-DYN
1
KÖB & SCHÄFER GmbH, Flotzbachstr. 33, A-6922 Wolfurt, Tel. +43/5574/6770-0, Fax 65707, E-Mail: [email protected]
We reserve the right to make technical changes.
3010-1
2007-01-31_E
Description
The PYROMAT-DYN is a burner with patented double combustion chamber. Which means that the burner system
enables optimized operation with automatic loading (wood chips, pellets) and may also be used with logs. A large loading
shaft with loading lid and separate grid has been fitted in front of the main combustion chamber to make loading wood
easy. In automatic operation, the burner system is suitable for all dry to moist wood fuels (max. W35). The control is
integrated into the burner system with connector-ready cabling to the sensors and motors. Which permits simple and
rapid installation. The PYROMAT-DYN has been tested and approved in accordance with the latest quality criteria in
compliance with EN 303-5 heating boilers for solid fuels,
CE certification as per European Machinery Directive and continuous quality assurance by TÜV.
Max. flow temperature:
100°C
Max. operating pressure:
3.0 bar
Electric connection:
3 x 400V
Safety heat exchanger:
Built in the burner & ready for use
Function:
-
In manual operation, chopped wood and waste wood are degassed on the incineration grate situated before the
main combustion chamber. Simultaneous operation with automatic loading is not possible.
-
In automatic operation the feed auger conveys the material to be burned into the main combustion chamber for
degasification.
The fasteners for the burn-back sensor and the thermally operated extinguisher valve are situated on the conveyor
pipe. Above the auger is the metering container with a light barrier to set the level of the fuel isolating layer required
by TRD 414.
-
In automatic operation the material to be incinerated is ignited automatically by an electric hot air blower.
The combustion gases are entirely burned out in the afterburn chamber together with secondary airflow.
-
The ash is removed from the main combustion chamber by the ash remover and then falls into the ash pan.
-
In the upright pipe heat exchanger, the thermal energy from the combustion gases is transferred to the boiler water.
The vertical surfaces of the heat exchanger are regularly cleaned by motor-driven, moving coil springs.
-
The speed-controlled exhaust fan was specially designed for operation in wood heating systems and is very quiet.
The negative pressure created by it produces a high degree of safety against burn-back in automatic operation and a
convenient feed function in manual operation.
-
An integrated heat management system (accumulator-temperature-guided with return circuit valve) enables the best
possible controlled operation.
Comes with:
-
Boiler with double combustion chamber, ash pan, kindling and cleaning utensils, coil springs for the heat exchanger
cleaning system, position sensor and mechanical drive for the ash remover completely installed
-
Exhaust fan, plug-and-play
-
Integrated ECOTRONIC control system (decentralised microprocessor system via CAN-bus), consisting of:
Boiler control panel, control module for mounting preferably on a wall, bus cable for the drive motors wired to output
plug
-
Feed auger with isolating layer, incl. Starttec drive via CAN-bus (including data transmission line) for gentle start-up,
automatic reversing and overload safeguard, light barriers for combustion chamber and metering container
-
Automatic ignition device
-
Boiler plant group ready-installed on connecting flange, consisting of boiler pump, two blockage units, boiler control
valve, forward flow sensor and return flow sensor, incl. the fittings
-
Three KTY heat accumulator sensors, incl. dipping shell (1/2" x 280 mm long) wired together to plug
-
Four-pin master switch, uninstalled (for installation near the control module)
ACCESSORIES for PYROMAT-DYN (Article KPM-…) at extra charge:
Name
Article
Text
Sizes
Use
Reduction exhaust connection
KPM-…
3110
3110
existing chimney 180 mm dia.
Exhaust gas fan - intake piece 90°
KPM-…
3110
3110
special exthaust gas conveyance
Exhaust gas deduster
KPM-…
3110
3110
optional
ECO function for PYROMAT-DYN
LSR-DYN
3200
-
for use with logs; incl. storage
Error report 230V
ECO-ZA
3200
-
optional
External requirements
ECO-ANF
3200
-
optional
Discharge systems
ADE/ADF
3300
3300
material transport silo to burner
Heater control, module extensions
ECO-…
4000ff -
optional
Data cable for operating module
ECO-…
4020
-
required
Burner safety devices
K-…
4500 -
optional
Extinguishing equipment
K-…
4550
4550
optional