Telescope Single Sided Table Bases with Beam
(with or without Utility Tray), Stand-Alone Application
INSTALL UTILITY TRAYS (WHERE APPLICABLE):
19. Insert (2) pairs of ¼ -20 x
5
/
8
" flanged button
head hex machine screws (W) loosely into
the threaded inserts on the inner face of
the crossbars. Leave a gap of about
3
/
16
"
beneath the head of the screws. Slip the
Utility Tray between the crossbars and
engage the upper screws into the upper
slot on the tray end plate. Rotate the tray so
the lower screws engage the bottom slot.
Tighten the screws with an Allen wrench.
20. Insert a M6-1 spring nut (Y) into the slot on the
front face of the center beam.
Position a Utility Tray Bracket (X) in front of the
spring nut (Y) and engage the back edge of the
utility tray within the grooves of the tray bracket.
Fasten the tray bracket to the spring nut with a
M6 - 1 x 14mm flat head machine screw (Z).
LEVEL TABLE:
21. Place the table in its final position and level
by extending the leveling glides as needed.
22. Pay close attention to column orientation.
Ensure both columns are truly vertical
and, in-particular, parallel to each other.
23. When levelers are extended more
than ½", it may be desirable to install
the Helical Glide Shroud. See Helical
Glide Installation Instructions.
INSTALL THE HEIGHT ADJUSTMENT
ELECTRICAL COMPONENTS:
24. For each station, decide if the
Handset Control Switch (I) will be on
the left or right side of the table.
NOTE:
If a return assembly is to be attached to the
primary surface, the handset should be temporarily
located on the same side as the return attachment.
It will ultimately be relocated to the return assembly.
25. Plug the handset cable into a housing
outlet on the chosen side. Connect one
end of the iDrive Cable into the second
outlet on that side and the other end into
an outlet on the opposite side of the table,
(see User Manual for cable diagram).
26. Insert the Power Supply plug into the
remaining outlet on the non-handset side.
Insert the power cord into the power
supply and position the power supply on
the nearest Transformer Shelf (G) so that
the green LED is visible from below.
PERFORM A RESET FOR THE PAIR
OF COLUMNS IN EACH STATION:
27. Plug the power supply into a temporary
power source. Ensure the green
LED on the power supply lights.
28. Apply approximately 100 lbs of weight to the
rails. Press and hold both UP and DOWN
buttons for ten seconds. After releasing the
buttons, press and hold the DOWN BUTTON
until both columns bottom out. Press the
UP button and the station will be ready to
perform normally. Remove the weight. Run
the station all the way up and down again to
ensure there are no issues with the columns.
Exploded Single Sided Table Base Assembly,
Steps 19-20: Utility Tray Installation
Step 20
M6-1 Spring Nut (Y)
Utility Tray Bracket (X)
M6-1 x 14mm Flat Head
Machine Screw (Z)
Utility Tray
Step 19
Threaded Inserts
¼
-20 x
5
/
8
" Flanged Button
Head Hex Machine Screw (W)