![Knick Stratos Pro A201COND Скачать руководство пользователя страница 53](http://html.mh-extra.com/html/knick/stratos-pro-a201cond/stratos-pro-a201cond_user-manual_1980116053.webp)
53
Configuration
Menu item
Action
Selection
Concentration
determination
For concntration
measurement only
Use the arrow keys
to select the desired
concentration solution.
Press
enter
to confirm.
-01- (NaCl),
‑02‑ (HCl),
‑03‑ (NaOH), ‑04‑ (H
2
SO
4
),
‑05‑ (HNO
3
), ‑06‑ (H
2
SO
4
),
‑07‑ (HCl), ‑08‑ (HNO
3
),
‑09‑ (H
2
SO
4
), ‑10‑ (NaOH),
‑U1‑
-U1-: Specifying a Concentration Solution for Conductivity Measurement
To specify a custom solution, 5 concentration values are entered in a matrix
together with 5 temperature values 1 ... 5. First enter the 5 temperature values,
then the corresponding conductivity values for each of the concentrations 1 ... 5.
These solutions are then available as “U1” in addition to the default standard
solutions.
Press
enter
to confirm
Use the arrow keys
to enter
temperature values 1 ... 5.
Press
enter
to confirm.
Input range:
–50...250 °C /
–58...482 °F
Use the arrow keys
to enter
concentration value 1.
Press
enter
to confirm.
For concentration value 1:
Use the arrow keys
to enter
conductivity values for
temperatures 1 ... 5.
Press
enter
to confirm.