Use
Diaphragm pump N0150 EX
6
Translation of Original Operation and Installation Instruction, english, KNF 321729 11/19
No overpressure may be applied to the suction side of the pump.
This function can be made possible on a project basis upon consultation
with KNF Customer Service.
2.3 Use in potentially explosive areas
In potentially explosive areas (zones), only operate pumps of the appropri-
ate device category and temperature class.
The pumps have the following explosion protection designation:
Designation
Description
Symbol for explosion-proof pumps
II
Device group (See Chapter
2/2G
Ex
Symbol indicates that the device complies with
one or more ignition protection types
H
Symbol for ignition protection type (See Chapter
II B + H2
T3
Temperature class (see Chapter
)
Gb
Equipment protection level (See Chapter
Equipment protection level for gas
Special operating conditions (See Chapter
Tab.5
An ignition hazard assessment in accordance with standards DIN EN ISO
80079-36 and DIN EN ISO 80079-37 was performed for the pumps. The
protective goals were reached by applying ignition protection type con-
structional safety "c".
The explosion protection designation can also be found at the following lo-
cation:
§
Type plate of the pump
Motor The pump motor must have at least the same explosion protection as the
pump.
2.4 Explanations of the explosion protection designation
2.4.1 Device groups
Device group I Device group I applies for devices that are used in underground plants of
mines as well as their underground systems that could be endangered by
methane and/or combustible dusts.
Device group II Device group II applies for devices that are used in other areas that could
be endangered by an explosive atmosphere.