
Servicing
Diaphragm pump N0150 EX
40
Translation of Original Operation and Installation Instruction, english, KNF 321729 11/19
9.4 Checking and replacing sprocket on coupling
Requirements
à
Disconnect the motor from mains and ensure that it is voltage-free.
à
Allow the pump and the motor to cool.
CAUTION
Risk of burns from hot pump parts
The pump head or motor may still be hot after op-
eration of the pump.
à
Allow the pump to cool after operation.
CAUTION
Personal injury and/or property damage due to in-
correct or improper transport of the motor
In the event of incorrect or improper transport, the
motor can fall down, be damaged or injure per-
sons.
à
Use suitable auxiliary means if necessary
(carrying strap, lifting gear, etc.).
à
Where appropriate, wear suitable personal
protective equipment (e.g., safety shoes,
safety gloves).
Tool and material
Quantity
Tool/material
1
Size 13 open-end wrench with torque indicator
1
Feeler gauge 3 mm
1
Test adapter for coupling (see Chapter
)
1
Open-end wrench 8 mm
Tab.43
Spare parts
Spare part
Position designation
Quantity
Sprocket
(4)
1
Tab.45
Содержание N0150 EX
Страница 49: ......
Страница 50: ......
Страница 51: ......
Страница 52: ......
Страница 140: ...KNF worldwide You can find our local KNF partners at www knf com ...