Servicing
Diaphragm pump N0150 EX
32
Translation of Original Operation and Installation Instruction, english, KNF 321729 11/19
9 Servicing
9.1 Servicing schedule
WARNING
Risk of explosion from wear
à
Have the connecting rod bearing replaced by
KNF according to servicing schedule.
à
Have the motor bearing replaced by KNF ac-
cording to servicing schedule.
WARNING
Risk of explosion if original parts are not used
If original parts are not used, the pump loses its
explosion protection properties. Furthermore, the
function of the pump and it safety are lost.
The validity of the CE conformity is rendered void
if original parts are not used.
à
Use only original parts from KNF during ser-
vicing work.
Component
Servicing interval
Pump
à
Inspect the pump periodically for
external damage or leakage
Connecting rod bearing
à
Have replaced after 17,000 op-
erating hours or after no more
than 24 months
Motor bearing
à
See the operating and installa-
tion instructions for the motor;
inquire with the manufacturer of
the motor if necessary
Gas connections
à
Inspect the pump periodically for
external damage or leakage
Coupling
à
Inspect coupling play periodi-
cally
à
See operating instructions for
coupling
Tab.37
Содержание N0150 EX
Страница 49: ......
Страница 50: ......
Страница 51: ......
Страница 52: ......
Страница 140: ...KNF worldwide You can find our local KNF partners at www knf com ...