Safety
Diaphragm pump N0150 EX
12
Translation of Original Operation and Installation Instruction, english, KNF 321729 11/19
Working with combustible media Make certain that the temperature of the medium is always sufficiently be-
low the ignition temperature of the medium so as to prevent ignition or ex-
plosion. This also applies for abnormal operating situations.
Note here that the temperature of the medium increases when the pump
compresses the medium.
Therefore, make certain that the temperature of the medium also remains
sufficiently below the ignition temperature of the medium even when it is
compressed to the maximum permissible operating pressure of the pump.
The maximum permissible operating pressure of the pump is stated in
Chapter
Make certain that the permissible ambient temperature (
)
is not exceeded.
If applicable, also take into consideration external energy sources (e.g., ra-
diation sources) that could add heat to the medium.
In case of doubt, contact KNF Customer Service.
Environmental protection Store and dispose of all replacement parts in accordance with environmen-
tal regulations. Observe the respective national and international regula-
tions. This applies in particular to parts that are contaminated with toxic
substances.
EU/EC directives/standards See EC/EU Declaration of Conformity
Customer service and repairs The pumps are maintenance-free. KNF does, however, recommend peri-
odically inspecting the pumps for noticeable changes to noises and vibra-
tions.
Only have repairs to the pumps performed by the responsible KNF Cus-
tomer Service.
Housings with live components may only be opened by specialist person-
nel.
Use only original parts from KNF during servicing work.
Only have repairs to the motors performed by the responsible KNF Cus-
tomer Service.