Assembly Instructions for the Temparuture Sensor of Cold Water Inlet and Hot Water Outlet
1.
Plug off the power cord.
3.
Separate hot water outlet temperature Probe by rotating
2.
Separate cold water inlet temperature Probe, fixed on
counterclockwise.
the pipe, by rotating counterclockwise.
4.
In reverse order, assemble them.
Assembly Instructions for Flow sensor and Reducing valve.
1.
Plug off the power cord.
3.
After disjoin the clip from water flow sensor, dismantle it.
2.
After disassemble screws fixed on the water inlet
4.
In reverse order, assemble them. And check the insertion
connection, separate Reducing valve.
of O-ring.
5
5-3 Fan unit
6
Hot Water Outlet Temp. Probe
Cold Water Inlet Temp. Probe
1
2
Water Flow Sensor
Reducing Valve
Water Inlet Connection
1
2
3