2-3-7 Installing flue (Fitting The Flue (Cont) )
A
Directly below an opening, air brick, opening widow, etc.
B
Above an opening, air brick, opening window etc
C
Horizontally to an opening, air brick, opening window etc
D
Below gutters, soil pipes or drain pipes
E
Below eaves
F
Below balconies or car port roof
G
From a vertical drain pipe or soil pipe
H
From an internal or external corner
I
Above ground, roof or balcony level
J
From a surface or boundary line facing a terminal
K
From a terminal facing a terminal (Horizontal flue).
From a terminal facing a terminal (Vertical flue).
L
From an opening in carport (e.g. door, window) into the dwelling
M
Vertically from a terminal on the same wall
N
Horizontally from a terminal on the same wall
R
From adjacent wall to flue (vertical only).
S
From an adjacent opening window (vertical only).
T
Adjacent to windows or openings on pitched and flat roofs
U
Below windows or openings on pitched roofs
300mm
300mm
1200mm
1200mm
25mm
25mm
25mm
600mm
300mm
2000mm
600mm
300mm
25mm
25mm
300mm
300mm
1000mm
1500mm