2) Gas conversion
The following adjustment and conversion operations must be carried out by qualified personnel. KITURAMI
Limited accepts no liability for damage to property or personal injury resulting from tampering with the water heater by
unauthorized persons.
To convert the water heater from
Natural Gas
to
LPG
and vice versa, the main burner injectors must be replaced.
Minimum and maximum pressure must then be adjusted on the gas valve.
Table1, Gas valve 2nd pressure each Model
Unit mmAq
MAX
MIN
MAX
MIN
MAX
MIN
MAX
MIN
83
24
79
18
92
19
105
16
57
18
57
16
53
12
64
12
Table2, Nozzle diameter each model and gas
Unit mm
UNIT 15
GAS
UNIT 10
UNIT 8
UNIT 10
UNIT 13
Ø1.1 x 17EA
UNIT 8
UNIT 13
UNIT 15
Model
3-6 Adjustment and gas Conversion
LPG
LNG
LPG
Model
Ø1.1 x 13EA
Ø1.1 x 10EA
Ø1.1 x 15EA
Ø1.68 x 15EA
Ø1.68 x 17EA
LNG
Ø1.55 x 13EA
Ø1.55 x 10EA
Potential
meter
maximum control
Potential
meter
minimum control
DIP Switch
Water column