6-4
Refrigerator
Compartment
(RC) Too Warm
PROBLEM
POSSIBLE CAUSE
TEST PROCEDURE/ACTION
See “Control Setting” section.
See “RC Thermistor” section.
See “Door Switch” section.
See “Air Door” section.
Check for any restriction to the airflow in the
RC and FC.
Cold air for the RC is drawn from the FC.
Check for proper FC temperatures (see “FC
Compartment Too Warm”).
See “Air Door” section.
See “Evaporator Fan” section.
See “Evaporator Fan” section.
See “Main Control Board” section.
See “Compressor” section.
See “Condenser Fan” section.
See “Inverter” section.
RC control set too warm.
RC thermistor.
Refrigerator light not shutting off.
Air door stuck closed or inoperative.
Blocked air flow.
Warm FC temperature.
Reversed air door wiring.
Evaporator fan not running or not running
up to speed.
Frost blocking evaporator air flow.
Main control board.
Compressor not operational.
Condenser fan not operational.
Inverter not operational.
Refrigerator
Compartment
(RC) Too Cold
RC control set too cold.
RC thermistor.
Air door stuck open.
Air door seal missing, damaged or re-
versed.
Reversed thermistor wiring.
Main control board.
See “Control Setting” section.
See “RC Thermistor” section.
See “Air Door” section.
A missing seal will let cold evaporator air
bypass the air door.
See “RC Thermistor” section.
See “Main Control Board” section.
Freezer Com-
partment (FC)
Too Warm
FC control set too warm.
FC thermistor.
Freezer light not shutting off.
Evaporator fan not running or not running
up to speed.
Condenser fan not running.
Frost blocking evaporator air flow.
Thermistor wires reversed.
Main control board.
Compressor not operational.
Inverter not operational.
See “Control Setting” section.
See “FC Thermistor” section.
See “Door Switch” section.
See “Evaporator Fan” section.
See “Condenser Fan” section.
See “Evaporator Fan” section.
See “FC Thermistor” section.
See “Main Control Board” section.
See “Compressor” section.
See “Inverter” section.
Freezer
Compartment
(FC) Too Cold
FC control set too cold.
Temperatures are –5
°
F in the FC and
34
°
F in the RC.
FC thermistor.
Open evaporator fan feedback.
Main control board.
See “Control Setting” section.
Refrigerator operating in the “Max Cool”
mode. Press the “Max Cool” button to re-
turn to normal operation.
See “FC Thermistor” section.
See “Evaporator Fan” section.
See “Main Control Board” section.
“Call Service”
Icon Lights
And Alarm Is
Sounding
Open evaporator fan feedback.
RC is over 48
°
F or the FC is over 15
°
F for
more than 3 hours.
Failed thermistors.
See “Evaporator Fan” section.
See “Over Temperature” section.
See “RC & FC Thermistor” sections.
TROUBLESHOOTING CHART
RC = Refrigerator Compartment FC = Freezer Compartment
Содержание 2003 M
Страница 10: ...1 6 NOTES ...
Страница 60: ...4 36 NOTES ...
Страница 80: ...6 10 NOTES ...
Страница 81: ...7 1 WIRING DIAGRAMS STRIP CIRCUITS SXS NON DISPENSER WIRING DIAGRAM 115 VOLTS 60 HZ ...
Страница 82: ...7 2 SXS DISPENSER WIRING DIAGRAM ...
Страница 83: ...7 3 BOTTOM MOUNT WIRING DIAGRAM ...
Страница 84: ...7 4 MAIN CONTROL BOARD BLOCK DIAGRAM ...
Страница 85: ...7 5 ELECTRONIC TEMPERATURE CONTROLLED MEAT PAN DIAGRAM ...
Страница 93: ...8 3 NOTES ...
Страница 94: ...8 4 NOTES ...
Страница 96: ......