6-7
TEST PROCEDURE/ACTION
Compressor
Inoperative.
Check to make sure that it is not on the 7
minute delay. Ohm the compressor. The
compressor should be 6 to 7
Ω
. If no resis-
tance is present, replace compressor.
See “Inverter” section to check the inverter.
If a mechanical clanking noise is evident,
replace the compressor. If the consumer is
complaining about varying sound level, ex-
plain the variable speed operation of the
compressor to them.
Noisy.
Condenser Fan
Not operational / not running.
Blocked.
Noisy.
Check for blade hits. Check the mounting
system.
Control Setting
RC control set too warm.
FC control set too warm.
RC control set too cold.
FC control set too cold.
Change to a colder temperature setting. A
mid point setting will deliver approximately
37
°
F in the RC, and 0
°
F in the FC in most
usage and ambient conditions.
Change to a warmer temperature setting. A
mid point setting will deliver approximately
37
°
F in the RC and 0
°
F in the FC in most
usage and ambient conditions.
Door Open Alarm
No display, no interior lights.
Door Switch
No display, no interior lights.
RC control set too warm.
FC control set too warm.
Run control diagnostics to check condenser
fan operation in step 4. The condenser fan
runs independently of the compressor but is
a constant speed DC motor. Voltage is sup-
plied to the condenser fan by a relay on
main control board. Voltage should be
present at pin 1 of connector 6 of the main
control board during operation (see the dia-
gram on page 7-2).
If either door is open for more than ten min-
utes, the control will turn off the light circuit.
This includes the control user interface in
the RC. The user interface is powered down
when the RC door is closed and is inactive.
The Door Open indicator light will flash and
an audio alarm will sound. The probable
cause is a failure of the light switch actuator
to cause the switch to change position.
The actuating mechanism of the light switch
is attached directly to the top door hinge pin.
If the door is set low the actuator blade my
not contact the rocker style light switch. The
quickest repair is to raise the affected door
until the mechanism operates properly. Align
the second door to match the first. Make
sure the metal is clean.
RC = Refrigerator Compartment
FC = Freezer Compartment
COMPONENT
SYMPTOM
Содержание 2003 M
Страница 10: ...1 6 NOTES ...
Страница 60: ...4 36 NOTES ...
Страница 80: ...6 10 NOTES ...
Страница 81: ...7 1 WIRING DIAGRAMS STRIP CIRCUITS SXS NON DISPENSER WIRING DIAGRAM 115 VOLTS 60 HZ ...
Страница 82: ...7 2 SXS DISPENSER WIRING DIAGRAM ...
Страница 83: ...7 3 BOTTOM MOUNT WIRING DIAGRAM ...
Страница 84: ...7 4 MAIN CONTROL BOARD BLOCK DIAGRAM ...
Страница 85: ...7 5 ELECTRONIC TEMPERATURE CONTROLLED MEAT PAN DIAGRAM ...
Страница 93: ...8 3 NOTES ...
Страница 94: ...8 4 NOTES ...
Страница 96: ......