IOM/GK(P)/CONICAL ISSUE DATE: 10.11.2015
Page 14 LAST REV. DATE: 01.08.2019
Pump set must be lifted from the lifting holes provided using suitable four chain
lifting equipment.
Lifting of Pump set
2.6.3 Storage.
2.6.3.1 Temporary storage for up to six weeks.
If the pump unit is not to be used immediately it should be stored carefully in a
horizontal position, in a sheltered, dry location.
Additional rust preventive should be applied to all unpainted carbon
steel or cast iron parts and should not be removed until final installation.
2.6.3.2 Long Term Storage.
If the pump is not to be installed and operated soon after arrival, store it in a clean,
dry place, having slow, moderate changes in ambient temperature. Step should be
taken to protect the pump from moisture, dust, dirt, and foreign bodies. It is
recommended that the following precautions to be taken:
a) Ensure that the bearings are packed with the recommended grease, to prevent
moisture from entering around the shaft.
b) Remove the glands, packings and lantern rings from the stuffing box if the pump
is equipped in this manner. If the pump is equipped with mechanical seal,
dismantle and coat the seal with light oil.
c) Ensure that suction and discharge branches of the pump and all other openings
are covered with cardboard, wood or masking tape to prevent foreign objects
entering the pump.
d) If the pump is to be stored where there is no protective covering, it is advisable
to cover the unit with a tarpaulin or other suitable covering.