CONNECTING AND DIsCONNECTING ImPlEmENT
CONNECTION
1. Make sure to stop the engine be-
fore connecting it.
2. Move the double acting valve le-
ver forward and backward for 4
to 5 times to release the pressure
in the hydraulic line of the tractor.
otherwise, it is hard to connect the
couplers, and hydraulic fluid can be
sprayed from the line and get in to
your eyes while connecting them.
3. Remove any foreign material
around the male and female cou-
plers. If foreign material enters the
hydraulic components, it can lead
to malfunction of the system.
4. open the dust-proof cover of the
female coupler of the tractor and
insert the male coupler of the im-
plement. A clicking sound is heard
when the couplers are engaged.
5. pull the hydraulic hose of the im-
plement to check that the couplers
are properly connected.
6. Start the engine and check the op-
erating status and leakage.
3. When the cylinder is contracted,
the hydraulic fluid returned from
the cylinder is drained to the trans-
mission through the draining circuit
as the operating lever is operated
to the opposite direction from the
expansion position.
1. Make sure to stop the engine be-
fore disconnecting it.
2. Release any residual pressure in
the hydraulic hoses of the imple-
ment and tractor by operating the
double acting valve lever 4 to 5
times.
3. Remove any foreign material
around the couplers.
4. keep the implement balanced by
removing any load applied. (lower-
ing it onto the ground, for example)
If disconnecting the hose while
outer load is applied to the imple-
ment, it is hard to connect the
implement in the future.
5. Remove the male coupler by push-
ing the female coupler boss of the
tractor backward.
6. close the dust-proof cover of the
female coupler of the tractor. Wrap
the male coupler of the implement
with a plastic bag to prevent con-
tamination.
It is recommended to use the
double acting cylinder instead
of the single acting cylinder if
the implement will be operated
frequently and continuously.
If using the single acting cyl-
inder too frequently or for an
extended period of time, the
hydraulic fluid can be over-
heated, resulting in deteriora-
tion of the hydraulic parts’ du-
rability as the main relief valve
opens at cylinder contraction.
•
ImPORTANT
DIsCONNECTION
TG110-AU-05.indd 26
2013-01-22 오전 10:30:00
Содержание PX1002
Страница 2: ...TG110 AU 00 indd 2 2012 11 15 오후 5 24 31 ...
Страница 12: ...TG110 AU 00 indd 12 2013 03 15 오후 5 09 58 ...
Страница 34: ...MEMO MEMO TG110 AU 01 indd 22 2013 01 23 오후 8 33 52 ...
Страница 40: ...MEMO MEMO TG110 AU 02 indd 6 2013 03 15 오후 5 01 36 ...
Страница 117: ...MEMO MEMO TG110 AU 04 indd 63 2013 03 06 오후 5 18 55 ...
Страница 145: ...MEMO MEMO TG110 AU 05 indd 28 2013 01 22 오전 10 30 01 ...
Страница 210: ...9 9 Engine Troubleshooting 9 2 Tractor Troubleshooting 9 4 TROUBLESHOOTING TG110 AU 09 indd 1 2013 01 22 오전 10 31 51 ...
Страница 216: ...10 10 INDEX INDEX 10 2 TG110 AU 10 indd 1 2013 03 15 오후 5 14 50 ...