FP 25/50 E / FP 25/50 D / FP 10/50 A
Repair and Adjustments
Issue: 04/2011
69
up to 7000 W xenon bulbs:
• Loosen the bulb support and put it down.
• Put the protective bonded fabric or a strong cloth around the unpacked bulb.
• Loosen the bulb fixing screw with an Allen key through the lamphouse opening.
• Remove the bulb and then the adapter on the bulb socket by loosening the fixing
screw.
• Pack the used xenon bulb.
• Fasten adapter onto the new xenon bulb (arrow) - bulb is packed in protective bonded
fabric.
• Thread the xenon bulb through the central mirror hole and fasten it by tightening the
Allen screw from the lamphouse outside.
Before inserting the 7,000 W bulb, turn the axial adjustment so far as possible in
forward direction to get more space.
• Remove the protective coat and connect the anode cable to the lamphouse socket.
ATTENTION
U
Position the anode cable away from any metal components as far as possible espe-
cially when inserting xenon bulbs with 40 cm anode cable.
U
Do not mechanically stress the anode cable to avoid bulb explosion.
$
The bulb support stays down for adjusting the screen illumination.
• Close the lamphouse door.
Содержание FP 10 A
Страница 2: ......
Страница 21: ...FP 50 D Installation Mounting Issue 10 2010 11 2 3 2 Important Hints for Installation Projector Dimensions ...
Страница 64: ...FP 50 D Issue 04 2011 54 ...
Страница 86: ...FP 25 50 E FP 25 50 D FP 10 50 A Issue 04 2011 76 ...
Страница 90: ...FP 50 D Issue 04 2011 80 Figure 2 Fig 2A Fig 2B 3B Fig 2C 3C Fig 2D 3D Figure 3 2A 2C 2B 3A Fig 3A 3B 3C ...
Страница 92: ...FP 50 D Issue 04 2011 82 Fig 5A Fig 5B Fig 5C Figure 5 5B 5C ...
Страница 98: ...FP 50 D Issue 04 2011 88 8 2 2 Basic Unit Overview ...