6 .4 .16 Adjusting the Intensity of Currents
X
NOTE
Z
Read the data sheet which is delivered with xenon bulb. The bulb manufacturer’s
own data should be used.
Z
Read also rectifier’s operating manual.
The intensity of currents associated to the installed xenon bulb can be adjusted on the
rectifier. The control can be operated by a potentiometer, a hand wheel, bridges, etc.
Lamp Capacity [W] Typical Current [A] Max . Current [A]
1000
50
55
1600
65
70
2000
70
85
2500
90
100
3000
100
110
4000
135
150
5000
140
150
7000
160
165
6 .4 .17 Checking the Light Arc Stabilizing Magnet
A magnet stabilizes the arc between cathode and anode. An even well adjusted light
arc provides a good optical efficiency and increase the life of the xenon lamp.
DANGER
S
An adjustment can only be carried out by service personnel.
S
An adjustment can only be carried out when xenon lamp is on. Therefore this
adjustment requires special protective equipment.
S
Adjustment must be carried out with a special welders’ mask and suitable protective
equipment.
Содержание FP 10 A
Страница 2: ......
Страница 21: ...FP 50 D Installation Mounting Issue 10 2010 11 2 3 2 Important Hints for Installation Projector Dimensions ...
Страница 64: ...FP 50 D Issue 04 2011 54 ...
Страница 86: ...FP 25 50 E FP 25 50 D FP 10 50 A Issue 04 2011 76 ...
Страница 90: ...FP 50 D Issue 04 2011 80 Figure 2 Fig 2A Fig 2B 3B Fig 2C 3C Fig 2D 3D Figure 3 2A 2C 2B 3A Fig 3A 3B 3C ...
Страница 92: ...FP 50 D Issue 04 2011 82 Fig 5A Fig 5B Fig 5C Figure 5 5B 5C ...
Страница 98: ...FP 50 D Issue 04 2011 88 8 2 2 Basic Unit Overview ...