FP 50 D
Issue: 10/2010
14
2 .4 .3 Connecting the Water Cooling (option)
ATTENTION
U
A water flow of 2 to 3 l/min is needed to get a water temperature of 18° C ± 2° C
(64° F ± 10° F).
U
The water temperature should not be less than 16° C, otherwise water can con-
dense on pipes, cables and film running components and finally results in damage
of the film material. At bad conditions dropping water can damage the electronics.
U
If possible the heat exchanger must not have more than 10 m distance to projector
and refrigerating set must not have more than 15 m distance to heat exchanger.
If environment temperature is high and wires are long, the hose is to be isolated
because of condensation water.
U
At bad climatic conditions (high temperature, high humidity) condensation can also
occur above 16° C - in this case please check the projector.
• Connect the inlet and outlet tubes of the water cooling system to the connecting
pieces in the projector.
X
NOTE
You will find the description of the water cooling unit in the corresponding operating
manual.
2 .5
Connecting the Projector
Connect the projector to the mains current (insert the plug):
»
230 / 400 V or
»
120 / 208 V.
X
NOTE
You will find plans of terminal connections in chapter 8.2.
2 .6
Connecting the Non-Rewind System to the Projector
Install the non-rewind system.
X
NOTE
Z
You will find plans of terminal connection in chapter 8.2.
Z
For more information, see platter system’s operating manual.
Z
The roller set of the film guidance between projector and non-rewind system should
not be mounted until the projector has its final position to the screen.
Содержание FP 10 A
Страница 2: ......
Страница 21: ...FP 50 D Installation Mounting Issue 10 2010 11 2 3 2 Important Hints for Installation Projector Dimensions ...
Страница 64: ...FP 50 D Issue 04 2011 54 ...
Страница 86: ...FP 25 50 E FP 25 50 D FP 10 50 A Issue 04 2011 76 ...
Страница 90: ...FP 50 D Issue 04 2011 80 Figure 2 Fig 2A Fig 2B 3B Fig 2C 3C Fig 2D 3D Figure 3 2A 2C 2B 3A Fig 3A 3B 3C ...
Страница 92: ...FP 50 D Issue 04 2011 82 Fig 5A Fig 5B Fig 5C Figure 5 5B 5C ...
Страница 98: ...FP 50 D Issue 04 2011 88 8 2 2 Basic Unit Overview ...