FP 50 D
Operating Elements
Issue: 04/2011
45
4 .2
Projector Lamphouse
Ammeter
Operating hour counter
Fuse (6.3 A)
Main switch
Press button: IGNITE
4 .2 .1 Ammeter
The ammeter shows the set intensity of currents.
»
The small lamphouse (1000 to 2000 W) is equipped with a 100 A ammeter.
»
The big lamphouse (2000 to 7000 W) is equipped with a 200 A ammeter.
4 .2 .2 Operating Hour Counter
The operating hour counter shows the hours the xenon bulb has been in operation.
4 .2 .3 Fuse
If you put out the fuse the lamphouse is separated from mains.
ATTENTION
You have to screw out the fuse at all maintenance work and cleaning.
4 .2 .4 Main Switch
Toggle switch in position “I”:
The xenon lamp is ON. The ventilation runs after when the xenon lamp turns off.
Toggle switch in position “0”:
The xenon lamp is OFF.
Manually switch on or switch off
• Switch on the main switch (position “I”). The fan is running.
• Switch off the main switch (position “0”). The fan is off.
X
NOTE
The fan runs after (approx. 5 minutes) when the projector and the xenon lamp are
switched off. This thermal switch is operating with a temperature of 60° C.
If the temperature is less than 45° C the switch resets.
2
3
4
5
1
Содержание FP 10 A
Страница 2: ......
Страница 21: ...FP 50 D Installation Mounting Issue 10 2010 11 2 3 2 Important Hints for Installation Projector Dimensions ...
Страница 64: ...FP 50 D Issue 04 2011 54 ...
Страница 86: ...FP 25 50 E FP 25 50 D FP 10 50 A Issue 04 2011 76 ...
Страница 90: ...FP 50 D Issue 04 2011 80 Figure 2 Fig 2A Fig 2B 3B Fig 2C 3C Fig 2D 3D Figure 3 2A 2C 2B 3A Fig 3A 3B 3C ...
Страница 92: ...FP 50 D Issue 04 2011 82 Fig 5A Fig 5B Fig 5C Figure 5 5B 5C ...
Страница 98: ...FP 50 D Issue 04 2011 88 8 2 2 Basic Unit Overview ...