FP 50 D
Issue: 04/2011
46
4 .2 .5 Ignition Button
The xenon lamp automatically ignites when pushing the start button on the projector
operating panel.
You can manually ignite the xenon lamp by pushing the ignition button.
ATTENTION
Do not push this button for more than 0.5 seconds. The xenon bulb can be damaged
if you push for a longer time. If the xenon lamp does not ignite after you have pushed
the button two to three times, the ignition unit or the rectifier or the xenon bulb probably
have a defect.
4 .3
Rectifier
By turning the hand wheel, the iron core in the coils will be moved and the intensity of
current will be changed. The adjusted intensity of currents can be read on the
ammeter.
X
NOTE
Z
If you have an electronic rectifier the intensity of current is adjusted via a
potentiometer switch.
Z
Detailed information about the rectifier can be found in the corresponding operating
manual.
Z
Values for the intensity of currents, see chapter 6.4.16.