KINGFISHER
O W N E R ’ S M A N U A L
w w w . k i n g f i s h e r b o a t s . c o m
42
Back Up Bilge Pump:
The back up bilge pumps is located approximately 3” up onto the port side stringer at the
rear of the bilge. This bilge pump is an emergency back up pump and is wired directly to
the battery only. This pump is tripped by an internal float switch only. To test this pump,
Turn the small knob located on the back of the bilge pump, this lifts up on the float
paddle and trips the pump
Once the switch is tripped, the pump will turn on. Once correct operation is
confirmed, release the knob
IMPORTANT:
If the back up pump fails to work,
clean out the pump as described in the
‘cleaning a bilge pump section’.
Check the main 10 amp fuse that is located on the bilge
pumps positive lead to the battery and check that the battery system is fully charged and
operational.
After confirming the above, if the pump is still not working,
DO NOT
OPERATE THE BOAT
, consult a Kingfisher dealer.
Cleaning a Bilge Pump
IMPORTANT:
Before each time that the boat is operated, the bilge pumps should be
cleaned out thoroughly, tested and checked for any signs of wear or damage.
Remove the top section of the bilge pump by pressing in the two tabs located at
the sides of the pump body.
Depress both sides.
Lift up on the pump body to expose the pick up and strainer basket.