A Top Safety and Protection Solution In The Worldwide!
www.GSMalarmsystem.com
King Pigeon Hi-Tech. Co., Ltd. Page
12
of 30 Ver 1.1 File No.: S1000012
link-Output relay for 4 minutes.
2) After you enter the menu, the attribute of the zone will be displayed in the LCD, if
this zone has been assigned wireless sensor, will display “V”. If hasn’t been
assigned wireless sensor, means this zone is empty, you can assign new wireless
sensor to this zone. Press Up or down button on the keyboard to check the other
Zones. Press Enter to edit it. After you pressed the Enter button, you can select the
zone attribute, and then press Enter, you can see “Turn on the device” or “Please
trigger the new wireless sensor”. Then following the instruction to add the new
wireless sensor to the S100. For Remote control, it will display VVVV if the unit has
been assigned remote control. Both of them you can press Enter to re-assign new
wireless sensor or remote control to replace the existence one.
3) In the Edit RF Parts you can edit the attribute of the sensor as Normal or Stay Type. If
the system is under Stay Mode (Also said At House or Partial Armed), the sensor set
as Normal triggered will not alarm, the sensor set as Stay triggered will Alarm. If the
system is under Armed Mode, then all RF sensors triggered, will alarm. This is very
important to remember the sensor types of the system. This function is very useful
when you at house and need some sensors in working status (E.g.: the sensor
installed outer and gas and smoke detectors, etc.) and some sensors indoor not in
working status (e.g.: the sensors installed in the living room, bed room, etc.).
4) The S100 can accept total 16 wireless sensors to 16 wireless zones; each zone can
be assigned one wireless sensor, and renamed it by SMS Command. And 5 remote
controls.
5) Zone Serial Number, Default Zone Name and Zone Attributes Table.
Zone
SN.
Default Zone Name
Default Zone Attribute
01
Intrusion from Entry Door
Normal
02
Intrusion from Living Room
Normal
03
Intrusion from Bed Room 1
Normal
04
Intrusion from Bed Room 2
Normal
05
Intrusion from Bed Room 3
Normal
06
Intrusion from Front Balcony
Normal