background image

ELEVO

EN 

Instructions and warnings for installation and use

Made in Italy

Содержание ELEVO

Страница 1: ...ELEVO EN Instructions and warnings for installation and use Made in Italy...

Страница 2: ......

Страница 3: ...ming of the button linkedto the on board courtesy light 13 5 4 Deleting all memorised transmitter 14 5 5 Deleting a single transmitter 14 5 6 Remote tools free transmitter programming 14 6 Programming...

Страница 4: ...KING gates Customer Service Do not make alterations to the product in any way Improper use can only lead to malfunctions The manufacturer declines all liability for damage caused by arbitrary modific...

Страница 5: ...ycles up to 2 16 8 2 2 4 12 6 Table 3 Limits in relation to force required to move door leaf Force required to move leaf N Cycle reduction percentage Up to 200 100 200 300 70 300 400 25 The height of...

Страница 6: ...or increasing the range of the transmitters Paragraph 10 8 Pause time for automatic re closing adjustable to between 0 and 180 sec with knob Paragraph 4 2 Obstacle sensitivity adjustment with knob Par...

Страница 7: ...and cause malfunc tions fire or dangerous situations If the door includes an access door make sure that it does not obstruct normal travel Fit a suitable interlock system if necessary Only insert the...

Страница 8: ...8 EN 6 1 2 3 4 4a 4b 4c 7 B 5 A 12 A 10 11 E E 9 B D 8 D C 13 F...

Страница 9: ...leaving the gearmotor on the ground lift the guide from the front section and secure using two screws plugs or rivets according to the installation surface 03 Secure the brackets H using the screws I...

Страница 10: ...he rear mechanical stop R next to the carriage fig 23 and tighten the screw Q fully down Important Make sure the release cord can be pulled below a height of 1 8 m 23 Q R 3 3 Installation of other dev...

Страница 11: ...t 1 1 2 3 4 5 6 7 8 9 10 11 12 2 3 4 ON DIP 13 14 Flash Aerial Phototest S2Photo 0 VDC STOP START 24VDC S1Edge 24VDC Lock Table 5 Terminals Function Description 1 2 Flash 24V max 15W warning light 3 P...

Страница 12: ...unction is ac tivated The control unit automatically closes the leaves after the time set through the PAUSE knob see Paragraph 4 2 If the AUTO dip switch is put to OFF the automatic re closing functio...

Страница 13: ...s 11 12 To use this function the Lock AUX output must be set to courtesy light see Paragraph 13 1 STEP ACTION RESULT 1 PRESS THE RADIO BUTTON FOR 1 SECOND The red radio LED turns on in the fixed mode...

Страница 14: ...ot consult Paragraph 14 1 2 PRESS THE SET BUTTON FOR 1 SECOND The red radio LED flashes and the yellow set LED turns on in fixed mode 3 PRESS A BUTTON ON THE TRANSMITTER YOU WISH TO CANCEL The red rad...

Страница 15: ...ding slowdown see paragraph 6 2 STEP ACTION RESULT 1 MOVE THE DOOR TO HALF WAY POSITION 2 PRESS THE SET BUTTON FOR 1 SECOND The yellow set LED flashes if not consult Paragraph 14 1 3 PRESS THE SET FOR...

Страница 16: ...TON OR A BUTTON OF A PAIRED TRANSMIT TER OR CLOSE START WIRED CONTACT TO SET THE SLOWDOWN START POINT FOR NOT HAVE SLOWDOWN WAIT UNTIL THE MOVEMENT HAS BEEN COMPLETED The yellow set LED stays on in th...

Страница 17: ...RED RADIO LED AND YELLOW SET LED If when attempting to enter any programming scheme the Set Radio and Error LEDs flash fast three times it means that the control unit protection is activated See Para...

Страница 18: ...active during closing and opening phase This input is normally closed NC For infra red photocells and safety edges with micro switch contact The factory wire bridge connected to S2 Photo must be remo...

Страница 19: ...agraph 4 1 This input is a voltage free dry contact only Connecting power to this input will void warranty TIMER FUNCTION if START contact is kept closed for in stance through a timer controlled or b...

Страница 20: ...el backjump value setting 5 EVERY TIME THE SET BUTTON IS PRESSED THE VALUE CHANGES FROM 1 TO 6 STARTING FROM THE CURRENTLY SET VALUE 1 5 2 4 3 6 example 1 current backjump 3 after SET is pressed backj...

Страница 21: ...t as electric lock see Paragraph 13 1 if desired program the transmitter button for the START com mand see Paragraph 5 1 At every wired or transmitter start command the light will switch on for the se...

Страница 22: ...THE SET AND RADIO BUTTONS SIMULTANEOUSLY OR WAIT 10 SECONDS TO EXIT THE PROCEDURE The LEDs return to the normal operation configuration To control the AUX contact set as courtesy light a radio command...

Страница 23: ...In order to carry out the check on the safety devices the connected edges must be of the resistive type with 8 2 kOhm 14 Other functions To interrupt the following programming sequences at any time pr...

Страница 24: ...ol unit stops powering the mo tor s at the end of the travel 3 If not sufficient turn the POWER knob slightly clock wise and reprogram automation s movement 4 Avoid reduce slowdown travel phase see Pa...

Страница 25: ...the dimensions stated in table 1 and limits specified in tables 2 and 3 ELEVO power supply 230Vac 10 50 60Hz Max absorbed power 200 W Insulation class 1 a safety grounding system is required Emergenc...

Страница 26: ...EC of the European Parliament and of the Council of 17 May 2006 on machinery and amending Directive 95 16 EC recast in accordance with the following harmonised standards It is hereby declared that the...

Страница 27: ......

Страница 28: ...cturer s details Timbro Stamp Azienda Company Localit Address Provincia Province Recapito telefonico Tel Referente Contact person King Gates S r l Phone 39 0434 737082 Fax 39 0434 786031 info king gat...

Отзывы: